In Vitro Mean Red Blood Cell Volume Change Induced by Diode Pump Solid State Low-Level Laser of 405 nm

نویسندگان

  • Mustafa S. Al Musawi
  • Mohamad Suhaimi Jafar
  • Bassam T. Al-Gailani
  • Naser Mahmoud Ahmed
  • Fatanah Mohamad Suhaimi
  • Nursakinah Suardi
چکیده

OBJECTIVE This study was conducted to investigate the effects of low-level laser (LLL) doses on human red blood cell volume. The effects of exposure to a diode pump solid state (DPSS) (λ = 405 nm) laser were observed. BACKGROUND DATA The response of human blood to LLL irradiation gives important information about the mechanism of interaction of laser light with living organisms. Materials and methods Blood samples were collected into ethylenediaminetetraacetic acid (EDTA)-containing tubes, and each sample was divided into two equal aliquots, one to serve as control and the other for irradiation. The aliquot was subjected to laser irradiation for 20, 30, 40, or 50 min at a fixed power density of 0.03 W/cm(2). Mean cell volume (MCV) and red blood cell (RBC) counts were measured immediately after irradiation using a computerized hemtoanalyzer. RESULTS Significant decrease in RBC volume (p < 0.05, p < 0.0001, p < 0.0001, and p < 0.05, respectively) was induced with variation in laser doses.The highest response was observed with an exposure time of 40 min. This result was reproduced in RBCs suspended in a buffered NaCl solution. In contrast to this finding, laser-induced RBC volume change was completely abolished by suspending RBCs in a solution containing a higher concentration of EDTA. CONCLUSIONS It was suggested that LLL can reduce RBC volume possibly because of the increased free intracellular Ca(+2) concentrations, which activate Ca(+2)-dependent K(+) channels with consequent K(+) ion efflux and cell shrinkage.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of Diode and He-Ne Laser on In Vitro Production of Anthocyanin in Apple Cell Suspension Culture

Plant cell cultures could be used as an important tool for biochemical production, ranging from natural pigments to pharmaceutical products. Anthocyanin is affected by a variety of factors. Light, an important plant environmental factor, influences the anthocyanin production in vegetative plant tissues. Here, we have investigated the influence of the blue laser-diode (BLD) and red laser-He Ne (...

متن کامل

Effect of Low Frequency Low-Level Infra-Red Diode Laser Therapy on Third Degree Burn Healing in Rats Skin

Purpose: The aim of present investigation was to evaluate low frequency low-level infra red diode laser therapy for a third degree burn healing in rats skin.Materials and Methods: 36 rats were divided into groups one and two. On day zero three third degree burns were made on the dorsum of each rat by steam. In group one ,first burn were exposed to a 80 Hz –pulsed 890 nm infra red diode laser wi...

متن کامل

Effect of Low Frequency Low-Level Infra-Red Diode Laser Therapy on Third Degree Burn Healing in Rats Skin

Purpose: The aim of present investigation was to evaluate low frequency low-level infra red diode laser therapy for a third degree burn healing in rats skin.Materials and Methods: 36 rats were divided into groups one and two. On day zero three third degree burns were made on the dorsum of each rat by steam. In group one ,first burn were exposed to a 80 Hz –pulsed 890 nm infra red diode laser wi...

متن کامل

Characterization of Petroleum Crude Oils using Laser Induced Fluorescence

The use of laser induced fluorescence (LIF) spectroscopy to characterize crude oil has privileges compared to conventional techniques in terms of reducing the size of sample, rapidity of measurements, high sensitivity and simplicity of sample handling and possibility of in situ measurements. The fluorescence radiation emitted from crude oil is the result of the interaction between the aromatic ...

متن کامل

Violet (405 nm) diode laser for laser induced fluorescence detection in capillary electrophoresis

The first application of the violet diode laser for laser induced fluorescence (LIF) detection in capillary electrophoresis is reported. Operating at 405 nm with an output power of 5 mW, this laser offers many advantages over conventional red diode lasers operating at 635 nm. We demonstrate the suitability of the violet diode laser for LIF detection by detecting amino acids labeled with naphtha...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 34  شماره 

صفحات  -

تاریخ انتشار 2016