3D MR angiography of renal arteries: comparison of volume rendering and maximum intensity projection algorithms.

نویسندگان

  • Ammar Mallouhi
  • Michael Schocke
  • Werner Judmaier
  • Christian Wolf
  • Andreas Dessl
  • Benedikt V Czermak
  • Peter Waldenberger
  • Werner R Jaschke
چکیده

PURPOSE To compare volume rendering (VR) and maximum intensity projection (MIP) as postprocessing techniques of magnetic resonance (MR) angiography for detection and quantification of renal artery stenosis. MATERIALS AND METHODS Twenty-seven patients underwent three-dimensional contrast material-enhanced MR angiography of the renal arteries with a 1.5-T imager. For each renal artery, targeted MIP and VR images were reconstructed in oblique coronal and transverse orientations. For each modality, image generation and evaluation were performed interactively by two independent radiologists blinded to angiographic results. In comparison with digital subtraction angiography (DSA) findings, stenosis quantification and detection by using MIP and VR were evaluated with the use of 50% and 70% cutoff points by using linear regression analysis and 2 x 2 tables. Overall image quality and vascular delineation on MIP and VR images were also compared. RESULTS All main and accessory renal arteries depicted at DSA were also demonstrated on MIP and VR images. VR performed slightly better than MIP for quantification of stenoses greater than 50% (VR: r(2) = 0.84, P <.001; MIP: r(2) = 0.38, P =.001) and significantly better for severe stenoses (VR: r(2) = 0.83, P <.001; MIP: r(2) = 0.21, P =.1). For detection of stenosis, VR yielded a substantial improvement in positive predictive value (VR: 95% and 90%; MIP: 86% and 68% for stenoses greater than 50% and 70%, respectively). Image quality obtained with VR was not significantly better than that with MIP; however, vascular delineation on VR images was significantly better. CONCLUSION The VR technique of renal MR angiography enabled more accurate detection and quantification of renal artery stenosis than did MIP, with significantly improved vascular delineation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Lmip: Local Maximum Intensity Projection | a New Rendering Method for Vascular Visualization |

In order to clearly depict densitometric as well as geometric information in vascular visualization from 3D data such as MR and CT angiographies, a new visualization method called local maximum intensity projection (LMIP) is proposed. LMIP is an extended version of MIP (maximum intensity projection). LMIP di ers from MIP in that the latter method selects the maximum value along an optical ray, ...

متن کامل

Inflow Inversion Recovery MR Angiography of Renal Arteries at 3.0 T: A Feasibility Study

Purpose Noncontrast MR angiography for the imaging of the renal vasculature at 1.5 T has been reported in several studies (1, 2). In recent years, 3.0-T MR systems are being used clinically because of the great advantage in signal-to-noise ratio. The aim of the present study was to evaluate the feasibility of noncontrast MR angiography of the renal arteries using an Inflow Inversion Recovery (I...

متن کامل

Local maximum intensity projection (LMIP): a new rendering method for vascular visualization.

PURPOSE The purpose of our study was to demonstrate a new visualization method (local maximum intensity projection; LMIP) that can clearly depict densitometric as well as geometric information in vascular visualization from 3D data such as obtained from MR and CT angiography. METHOD LMIP is an extended version of maximum intensity projection (MIP). However, LMIP differs from MIP in that the l...

متن کامل

Automatic bone removal in CT angiography

Figure 1. CT angiography workflow. CT angiography (CTA) allows arteries and veins in the brain and neck region to be made visible in a way that is significantly less invasive than conventional angiography. To fully comprehend the complex geometry of the vessels, a set of CTA images is often visualized using maximum intensity projection (MIP) or volume rendering (VR). In a MIP or VR image, howev...

متن کامل

Clinical usefulness of unsubtracted 3D digital angiography compared with rotational digital angiography in the pretreatment evaluation of intracranial aneurysms.

BACKGROUND AND PURPOSE Three-dimensional digital subtraction angiography (DSA) is useful as a supplement to 2D DSA in the pretreatment evaluation of intracranial aneurysms. However, the clinical efficacy of 3D digital angiography (DA) that is generated from unsubtracted rotational images has not been established. The purpose of this study was to assess whether 3D DA provides additional useful i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiology

دوره 223 2  شماره 

صفحات  -

تاریخ انتشار 2002