چکیده

BACKGROUND We observed that some patients with clinical leptospirosis supported by positive results of rapid tests were negative for leptospirosis on the basis of our diagnostic gold standard, which involves isolation of Leptospira species from blood culture and/or a positive result of a microscopic agglutination test (MAT). We hypothesized that our reference standard was imperfect and used statistical modeling to investigate this hypothesis. METHODS Data for 1652 patients with suspected leptospirosis recruited during three observational studies and one randomized control trial that described the application of culture, MAT, immunofluorescence assay (IFA), lateral flow (LF) and/or PCR targeting the 16S rRNA gene were reevaluated using Bayesian latent class models and random-effects meta-analysis. RESULTS The estimated sensitivities of culture alone, MAT alone, and culture plus MAT (for which the result was considered positive if one or both tests had a positive result) were 10.5% (95% credible interval [CrI], 2.7%-27.5%), 49.8% (95% CrI, 37.6%-60.8%), and 55.5% (95% CrI, 42.9%-67.7%), respectively. These low sensitivities were present across all 4 studies. The estimated specificity of MAT alone (and of culture plus MAT) was 98.8% (95% CrI, 92.8%-100.0%). The estimated sensitivities and specificities of PCR (52.7% [95% CrI, 45.2%-60.6%] and 97.2% [95% CrI, 92.0%-99.8%], respectively), lateral flow test (85.6% [95% CrI, 77.5%-93.2%] and 96.2% [95% CrI, 87.7%-99.8%], respectively), and immunofluorescence assay (45.5% [95% CrI, 33.3%-60.9%] and 96.8% [95% CrI, 92.8%-99.8%], respectively) were considerably different from estimates in which culture plus MAT was considered a perfect gold standard test. CONCLUSIONS Our findings show that culture plus MAT is an imperfect gold standard against which to compare alterative tests for the diagnosis of leptospirosis. Rapid point-of-care tests for this infection would bring an important improvement in patient care, but their future evaluation will require careful consideration of the reference test(s) used and the inclusion of appropriate statistical models.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Contrastive analysis of diagnostic tests evaluation without gold stand-ard: review article

Considering the advancement of medical sciences, diagnostic tests have been developed to distinguish patients from healthy population. Therefore, Determining and evaluation of the diagnostic accuracy tests is of great importance. The accuracy of a test under evaluation is determined through the amount of agreement between its results with the results of the gold standard, and this test accuracy...

متن کامل

A Meta-Analysis of Typhoid Diagnostic Accuracy Studies: A Recommendation to Adopt a Standardized Composite Reference

Novel typhoid diagnostics currently under development have the potential to improve clinical care, surveillance, and the disease burden estimates that support vaccine introduction. Blood culture is most often used as the reference method to evaluate the accuracy of new typhoid tests; however, it is recognized to be an imperfect gold standard. If no single gold standard test exists, use of a com...

متن کامل

Bayesian meta-analysis of diagnostic tests allowing for imperfect reference standards.

There is an increasing interest in meta-analyses of rapid diagnostic tests (RDTs) for infectious diseases. To avoid spectrum bias, these meta-analyses should focus on phase IV studies performed in the target population. For many infectious diseases, these target populations attend primary health care centers in resource-constrained settings where it is difficult to perform gold standard diagnos...

متن کامل

Application of the Novel CRISPR / Cas Technology in Diagnosis of COVID-19 Strains

The novel Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) has caused respiratory infection, resulting in more than two million deaths globally and hospitalizing thousands of people until 2021. A considerable percentage of the SARS-CoV-2 positive patients are asymptomatic or pre-symptomatic carriers, facilitating the viral spread in the community by their social activities. Hence, i...

متن کامل

Prospective Evaluation of Three Rapid Diagnostic Tests for Diagnosis of Human Leptospirosis

BACKGROUND Diagnosis of leptospirosis by the microscopic agglutination test (MAT) or by culture is confined to specialized laboratories. Although ELISA techniques are more common, they still require laboratory facilities. Rapid Diagnostic Tests (RDTs) can be used for easy point-of-care diagnosis. This study aims to evaluate the diagnostic performance of the RDTs LeptoTek Dri Dot, LeptoTek Later...