Minimization of the preanalytical error in plasma samples for pharmacokinetic analyses and therapeutic drug monitoring--using doxorubicin as an example.
نویسندگان
چکیده
BACKGROUND There are many sources of variability in plasma samples drawn for pharmacokinetic analyses or therapeutic drug monitoring. In this article, methods are proposed on how to prevent sample dilution (Part I) and contamination effects (Part II) in plasma samples, using doxorubicin as an example. METHODS Experiments were performed in the laboratory setting to identify factors that could influence plasma samples in clinical practice. In part I, it was hypothesized that saline solution left in a catheter could lead to a dilution of samples drawn through this catheter. The impact of 2 different sampling techniques, the "discard method" and the "push-pull method", was examined. In part II, an infusion system was filled with a 1 mg/mL solution of doxorubicin. After rinsing the system with increasing volumes of saline solution, the drug concentration of the fluid left in the system was analyzed. Furthermore, plasma samples were drawn through the drug administration catheter, and the contamination of these samples with doxorubicin left in the catheter was measured. RESULTS In part I, a discard volume of plasma equal to 4 dead volumes of the sampling line was necessary to avoid dilution of a sample taken from a port or double-lumen catheter filled with saline solution ("discard method"). Pulling up and down the same volume through the catheter 5 times ("push-pull method") was proved to be an alternative with no need to discard blood. In part II, after rinsing the infusion system with a volume of saline solution corresponding to 4 dead volumes of the system and after discarding a volume of plasma corresponding to 4 sampling line volumes, the doxorubicin contamination in the samples was negligibly small. CONCLUSIONS Under the described conditions, the push-pull method delivered the same results as the discard method to prevent sample dilution. To avoid contamination in plasma samples, development of standardized sampling procedures seems to be essential and feasible.
منابع مشابه
A Simple and Sensitive HPLC Method for Fluorescence Quantitation of Doxorubicin in Micro-volume Plasma: Applications to Pharmacokinetic Studies in Rats
A validated HPLC method was developed to determine doxorubicin concentration in a small volume of rat plasma (60 µl) with convenient fluorescence detection. Sample preparation includes a simple one-step liquid-liquid extraction using minimum amount of organic solvent, with extraction recoveries more than 95%. The analysis was accomplished using PerfectSil C18 column maintained at 35 °C and a mo...
متن کاملA Simple and Sensitive HPLC Method for Fluorescence Quantitation of Doxorubicin in Micro-volume Plasma: Applications to Pharmacokinetic Studies in Rats
A validated HPLC method was developed to determine doxorubicin concentration in a small volume of rat plasma (60 µl) with convenient fluorescence detection. Sample preparation includes a simple one-step liquid-liquid extraction using minimum amount of organic solvent, with extraction recoveries more than 95%. The analysis was accomplished using PerfectSil C18 column maintained at 35 °C and a mo...
متن کاملA Review on Therapeutic Drug Monitoring of Immunosuppressant Drugs
Immunosuppressants require therapeutic drug monitoring because of their narrow therapeutic index and significant inter-individual variability in blood concentrations. This variability can be because of factors like drug-nutrient interactions, drug-disease interactions, renal-insufficiency, inflammation and infection, gender, age, polymorphism and liver mass. Drug monitoring is widely practiced ...
متن کاملPreparation, in-vitro characterization and pharmacokinetic evaluation of Brij decorated doxorubicin liposomes as a potential nanocarrier for cancer therapy
The aim of current study was to investigate the effect of Brij decoration of liposomes on in vitro and in vivo characteristics of the nanocarriers. Two hydrophilic Brij surfactants (Brij 35 and Brij 78) with almost similar molecular weight but differing in acyl chain were incorporated into liposomal bilayers at two percentages (5% and 10%). Conventional liposomes (CL) containing egg phosphatidy...
متن کاملRapid High Performance Liquid Chromatographic Method for Determination of Clarithromycin in Human Plasma Using Amperometric Detection: Application in Pharmacokinetic and Bioequivalence Studies
A rapid, sensitive and reproducible HPLC method using amperometric detector was developed and validated for the analysis of clarithromycin in human plasma. The separation was achieved on a monolithic silica column (MZ- C8 125×4.0 mm) using acetonitrile- methanol-potassium dihydrogen phosphate buffer (40:6:54,v/v), with pH of 7.5, as the mobile phase at a flow rate of 1.5 mL/min. The assay enabl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Therapeutic drug monitoring
دوره 33 6 شماره
صفحات -
تاریخ انتشار 2011