Hemodynamic Alterations Induced by Isoproterenol and Pacing After Aortic Valve Replacement with the Bjork-Shiley or St. Jude Medical Prosthesis

نویسندگان

  • J. THORMANN
  • M. GOTTWIK
  • M. SCHLEPPER
  • F. HEHRLEIN
چکیده

Stress evaluation was carried out in 26 patients approximately 7 months after aortic valve replacement with Bjork-Shiley valves (13 patients) and St. Jude medical valves (13 patients). During isoproterenol infusion (0.3 gg/kg/min), cardiac output increased by a factor of 1.5 and aortic valve area decreased by 50% for both valve groups, while transvalvular gradients (rest: 7 ± 2 vs 10 ± 5 mm Hg,p > 0.05) increased to 42 + 18 vs 51 ± 18 mm Hg (p > 0.05), i.e., to levels of moderate aortic stenosis. However, during pacing stress these values progressively decreased with rising heart rates. In other postoperative evaluations that included ergometric stress with isoproterenol and pacing, induced hemodynamic changes after aortic valve replacement were predictable and consistent with regard to both direction and magnitude, and they differed characteristically according to the type of stress used. We conclude that no functional differences between Biork-Shiley and St. Jude medical valves can be claimed. Standardized evaluation with isoproterenol is a sensitive stress test of prosthetic valvular hemodynamics. Because of the apparent magnification of residual obstruction after aortic valve replacement, it has advantages over pacing.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hemodynamics alterations induced by isoproterenol and pacing after aortic valve replacement with the Björk-Shiley or St. Jude medical prosthesis.

Stress evaluation was carried out in 26 patients approximately 7 months after aortic valve replacement with Björk-Shiley valves (13 patients) and St. Jude medical valves (13 patients). During isoproterenol infusion (0.3 micrograms/kg/min), cardiac output increased by a factor of 1.5 and aortic valve area decreased by 50% for both valve groups, while transvalvular gradients (rest: 7 +/- 2 vs 10 ...

متن کامل

CARDIOVASCULAR MEDICINE Twenty year comparison of a Bjork-Shiley mechanical heart valve with porcine bioprostheses

Objective: To compare survival and outcome in patients receiving a mechanical or bioprosthetic heart valve prosthesis. Design: Randomised prospective trial. Setting: Tertiary cardiac centre. Patients: Between 1975 and 1979, patients were randomised to receive either a Bjork-Shiley or a porcine prostheses. The mitral valve was replaced in 261 patients, the aortic in 211, and both valves in 61 pa...

متن کامل

Double Valve Replacement (Mitral and Aortic) for Rheumatic Heart Disease: A 20-year experience with 300 patients.

Introduction: Rheumatic heart disease still remains one of the leading causes of congestive heart failure and death owing to valvular pathologies, in developing countries. Valve replacement still remains the treatment of choice in such patients.The aim of this study wasto analyze the postoperative outcome of  double valve replacement (Mitral and Aortic ) in patients of rheumatic heart disease. ...

متن کامل

Twelve-year comparison of a Bjork-Shiley mechanical heart valve with porcine bioprostheses.

BACKGROUND Patients undergoing heart-valve replacement may receive a mechanical prosthesis, necessitating lifelong anticoagulant treatment, or a porcine bioprosthesis, which involves no absolute need for anticoagulants. METHODS We carried out a randomized, prospective trial to compare the durability of the Bjork-Shiley mechanical prosthesis (spherical tilting-disk model) and the incidence of ...

متن کامل

Echocardiographic assessment of left ventricular filling characteristics after mitral valve replacement with the St Jude medical prosthesis.

The major cause of late mortality and morbidity after prosthetic valve replacement is thromboembolism. The nidus for initiation of thrombus formation has been blood metal interfaces, and a new valve--the St Jude prosthesis--has therefore been developed without any metal components. We have assessed echocardiographically in 27 patients the effects of this valve on left ventricular filling charac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005