Assessment of left atrial appendage function by transesophageal echocardiography. Implications for the development of thrombus.

نویسندگان

  • C Pollick
  • D Taylor
چکیده

BACKGROUND The predilection of the left atrial appendage (LAA) for thrombus formation has long been known. METHODS AND RESULTS We prospectively studied the two-dimensional echocardiographic and Doppler patterns of LAA function in 82 patients by transesophageal echocardiography. In the 63 patients in sinus rhythm, LAA area was measured during LAA diastole at the onset of the electrocardiographic (ECG) P wave (LAAmax) and after LAA systole at the ECG R wave (LAAmin) and LAA ejection fraction was calculated as (LAAmax-LAAmin)/LAAmax; peak Doppler velocity was recorded from the LAA outlet. The 58 patients in sinus rhythm without LAA thrombus were grouped according to left atrial size on transthoracic echocardiography; 39 patients had a left atrial size of less than 40 mm (group 1) and 19 had a left atrial size of 40 mm or greater (group 2). Five patients in sinus rhythm had LAA thrombus. In the 19 patients with atrial fibrillation or flutter LAAmax was measured independent of the ECG; three of these patients had LAA spontaneous contrast, four had thrombus, and one had both. Patients in sinus rhythm without LAA thrombus demonstrated a characteristic pattern of a contractile LAA apex and a noncontractile base with color flow and pulsed Doppler evidence of LAA emptying that coincided with the P wave. Patients in sinus rhythm with LAA thrombus had a mean +/- SD LAAmax (8.0 +/- 1.5 cm2) larger than that in group 1 (5.0 +/- 1.9 cm2) (p less than 0.01) but not group 2 (6.7 +/- 3.1 cm2), LAAmin (6.5 +/- 1.0 cm2) larger than that in both group 1 (2.3 +/- 1.5 cm2) and group 2 (4.2 +/- 2.7 cm2) (p less than 0.01), and LAA ejection fraction (17 +/- 11%) and LAA velocity (0.24 +/- 0.10 m/sec) less than those in both group 1 (55 +/- 21% and 0.48 +/- 0.24 m/sec, respectively) and group 2 (45 +/- 27% and 0.46 +/- 0.24 m/sec, respectively) (p less than 0.01). Patients with atrial fibrillation or flutter with LAA spontaneous contrast and/or thrombus had LAAmax (10.4 +/- 6.6 cm2) greater than that in patients with atrial fibrillation or flutter without LAA contrast and/or thrombus (6.8 +/- 3.0 cm2) (p less than 0.05). The LAA appeared as a static pouch in seven of eight of the former compared with in two of 11 of the latter. When attempted, Doppler demonstrated a recognizable fibrillatory LAA outflow velocity pattern in none of three in the former versus four of seven in the latter group. CONCLUSIONS We conclude that the LAA has a characteristic pattern of emptying in sinus rhythm. LAA thrombus formation in sinus rhythm and atrial fibrillation is associated with both poor LAA contraction and LAA dilation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Echocardiographic assessment of the left atrial appendage.

The left atrial (LA) appendage is a common source of cardiac thrombus formation associated with systemic embolism. Transesophageal echocardiography allows a detailed evaluation of the structure and function of the appendage by two-dimensional imaging and Doppler interrogation of appendage flow. Specific flow patterns, reflecting appendage function, have been characterized for normal sinus rhyth...

متن کامل

Assessment of left atrial and left atrial appendage flow and stasis in atrial fibrillation

Background Atrial fibrillation (AF) is associated with increased risk of stroke due to development of left atrial (LA) thrombus [1]. Thromboembolic risk is assessed by clinical risk scores (CHA2DS2-VASc). However, these scores have limited predictive value. Echocardiography studies have shown that physiologic factors such as decreased atrial blood flow and increased stasis (LA velocities <0.2m/...

متن کامل

Comparison of magnetic resonance imaging and transesophageal echocardiography in detection of thrombus in the left atrial appendage.

BACKGROUND AND PURPOSE A noninvasive technique of visualizing the left atrial appendage (LAA) and its thrombus in patients with atrial fibrillation would be of great interest. This study examined the utility of MRI for the assessment of thrombus in the LAA. METHODS We evaluated 50 subjects with nonrheumatic continuous atrial fibrillation and a history of cardioembolic stroke. Each patient rec...

متن کامل

Left atrial appendage function assessment and thrombus identification☆

BACKGROUND The diagnosis of thrombus in the left atrium in patients with persistent atrial fibrillation (AF) and may be inconsistent because of variability in thrombus morphology. In some cases it is challenging and requires unusual approach. New Doppler-derived methods might be helpful to identify such thrombi. We evaluated quantitative differences in mechanical function of the left atrial app...

متن کامل

Detection of left atrial appendage thrombus by cardiac computed tomography: a word of caution.

In this issue of iJACC, Martinez et al. (1) report their experience with cardiac computed tomography (CCT) to detect left atrial appendage thrombi in patients with atrial fibrillation undergoing pulmonary vein radiofrequency ablation. Atrial fibrillation is one of the most common cardiovascular disorders, carrying significant morbidity, including cardio-embolic stroke and heart failure. Slow fl...

متن کامل

Left atrial appendage mass: is it always a thrombus?

Myxoma is the most common benign tumor of the heart, but it is very rare for it to originate from the left atrial appendage. Distinguishing between a mass, a thrombus, and a tumor in the body of the left atrium with preoperative transthoracic or transesophageal echocardiography is very difficult, even more so in patients with mitral valve disease and chronic atrial fibrillation. A 50-year-old m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 84 1  شماره 

صفحات  -

تاریخ انتشار 1991