We have designed and tested a set of five miniature nested magnetic shields constructed of high-permeability material, with external volumes for the individual shielding layers ranging from 0.01 to 2.5 cm(3). We present measurements of the longitudinal and transverse shielding factors (the ratio of external to internal magnetic field) of both individual shields and combinations of up to three layers. The largest shielding factor measured was 6 x 10(6) for a nested set of three shields, and from our results we predict a shielding factor of up to 1 x 10(13) when all five shields are used. Two different techniques were used to measure the internal field: a chip-scale atomic magnetometer and a commercially available magnetoresistive sensor. Measurements with the two methods were in good agreement.
منابع مشابه
A highly flexible and compact magnetoresistive analytic device.
A grand vision of realization of smart and compact multifunctional microfluidic devices for wearable health monitoring, environment sensing and point-of-care tests emerged with the fast development of flexible electronics. As a vital component towards this vision, magnetic functionality in flexible fluidics is still missing although demanded by the broad utility of magnetic nanoparticles in med...
متن کاملTantalum/ Nitrogen and n-type WO3 semiconductor/FTO structures as a cathode for the future of nano devices
In the last decades an important number of research papers published on nano chip electrode and cathode electrochromic materials. Tantalum (Ta) with so high melting point can be as a good candidate for the future of nano chip devices. However, its surface has not enough trap centers and/or occupation states, so nitrogen ions exposed on Ta surafce, may solve this problem. For this purpose, in th...
متن کاملReliability characteristics of microfabricated Rb mini-lamps for optical pumping in miniature atomic clocks and magnetometers
With the rising need for microfabricated chip-scale atomic clocks to enable high precision timekeeping in portable applications, there has been active interest in developing miniature (<few cm), chip-scale alkali vapor lamps, since vapor plasma discharge sources are currently the standard for optical pumping in double-resonance clocks. We reported in 2012 a first microfabricated chip-scale Rubi...
متن کاملA compact, high performance atomic magnetometer for biomedical applications.
We present a highly sensitive room-temperature atomic magnetometer (AM), designed for use in biomedical applications. The magnetometer sensor head is only 2 × 2 × 5 cm3 and is constructed using readily available, low-cost optical components. The magnetic field resolution of the AM is <10 fT Hz–1/2, which is comparable to cryogenically cooled superconducting quantum interference device (SQUID) m...
متن کاملThree-Dimensional Interconnect Modeling for Nano-Scale VLSI Technologies
Designing high performance very large scale integration (VLSI) circuits has become more challenging than ever due to deep sub-micron effects and accelerating time-to-market cycles. With the increasing interconnect delay dominance and strong coupling effects, a small change in the design can cause new timing violations and result in design iterations. At the same time, the industry trend of inte...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Review of scientific instruments
دوره 78 8 شماره
صفحات -
تاریخ انتشار 2007