Single-pass attenuated total reflection Fourier transform infrared spectroscopy for the prediction of protein secondary structure.

نویسندگان

  • Brandye M Smith
  • Lisa Oswald
  • Stefan Franzen
چکیده

Principal component regression (PCR) was applied to a spectral library of proteins in H2O solution acquired by single-pass attenuated total reflectance (ATR) Fourier transform infrared (FT-IR) spectroscopy. PCR was used to predict the secondary structure content, principally alpha-helical and the beta-sheet content, of proteins within a spectral library. Quantitation of protein secondary structure content was performed as a proof of principle that use of single-pass ATR-FT-IR is an appropriate method for protein secondary structure analysis. The ATR-FT-IR method permits acquisition of the entire spectral range from 700 to 3900 cm(-1) without significant interference from water bands. An "inside model space" bootstrap and a genetic algorithm (GA) were used to improve prediction results. Specifically, the bootstrap was utilized to increase the number of replicates for adequate training and validation of the PCR model. The GA was used to optimize PCR parameters, particularly wavenumber selection. The use of the bootstrap allowed for adequate representation of variability in the amide A, amide B, and C-H stretching regions due to differing levels of sample hydration. Implementation of the bootstrap improved the robustness of the PCR models significantly; however, the use of a GA only slightly improved prediction results. Two spectral libraries are presented where one was better suited for beta-sheet content prediction and the other for alpha-helix content prediction. The GA-optimized PCR method for alpha-helix content prediction utilized 120 wavenumbers within the amide I, II, A, B, and IV and the C-H stretching regions and 18 factors. For beta-sheet content predictions, 580 wavenumbers within the amide I, II, A, and B and the C-H stretching regions and 18 factors were used. The validation results using these two methods yielded an average absolute error of 1.7% for alpha-helix content prediction and an average absolute error of 2.3% for beta-sheet content prediction. After the PCR models were developed and validated, they were used to predict the alpha-helix and beta-sheet content of two unknowns, casein and immunoglobulin G.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Single-pass attenuated total reflection Fourier transform infrared spectroscopy for the analysis of proteins in H2O solution.

The application of single-pass attenuated total reflection Fourier transform infrared (ATR-FT-IR) microscopy was investigated for secondary structure analysis of 15 representative proteins in H2O solution. This is the first reported application of single-pass ATR-FT-IR for protein analysis; thus, the method was validated using transmission FT-IR and multipass ATR-FT-IR as referee methods. The s...

متن کامل

Secondary structure and dosage of soluble and membrane proteins by attenuated total reflection Fourier-transform infrared spectroscopy on hydrated films.

Attenuated total reflection Fourier-transform infrared spectroscopy of thin hydrated films of soluble and membrane protein included in a phospholipid bilayer is shown to provide useful information as to the secondary structure of the protein. The analysis of the amide I band of deuterated samples by Fourier self-deconvolution followed by a curve fitting was performed by a new procedure in which...

متن کامل

Combined light microscopy and attenuated total reflection fourier transform infrared spectroscopy for integration of biofilm structure, distribution, and chemistry at solid-liquid interfaces.

Reflected differential interference contrast microscopy and attenuated total reflection Fourier transform infrared spectroscopy were used to obtain complementary data on the structural and chemical properties of a biofilm. This information was obtained nondestructively, quasisimultaneously, and in real time, thereby permitting the verification of time-dependent relationships between the biofilm...

متن کامل

Probing the secondary structure of bovine serum albumin during heat-induced denaturation using mid-infrared fiberoptic sensors.

Attenuated total reflection Fourier transform infrared (ATR-FTIR) spectroscopy using a special waveguide based on a silver halide fiber was used for probing the heat-induced secondary structure and conformation changes of bovine serum albumin (BSA). From the secondary derivative and the curve fitting of the obtained ATR-FTIR spectra, the changes of the BSA secondary structure with temperature w...

متن کامل

Attenuated total reflection Fourier transform infrared spectroscopy for on-chip monitoring of solute concentrations.

We report a cost-efficient Attenuated Total Reflection Fourier Transform Infrared Spectroscopy (ATR-FTIR) method for monitoring concentrations of solutes in solutions flowing through microfluidic channels. The method allows rapid acquisition of spectra and enables chemical characterisation and concentration measurements that are independent of the flow rate of liquids. The method enables indepe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Analytical chemistry

دوره 74 14  شماره 

صفحات  -

تاریخ انتشار 2002