Effects of Reusing Baseline Volumes of Interest by Applying (Non-)Rigid Image Registration on Positron Emission Tomography Response Assessments
نویسندگان
چکیده
OBJECTIVES Reusing baseline volumes of interest (VOI) by applying non-rigid and to some extent (local) rigid image registration showed good test-retest variability similar to delineating VOI on both scans individually. The aim of the present study was to compare response assessments and classifications based on various types of image registration with those based on (semi)-automatic tumour delineation. METHODS Baseline (n = 13), early (n = 12) and late (n = 9) response (after one and three cycles of treatment, respectively) whole body [(18)F]fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography (PET/CT) scans were acquired in subjects with advanced gastrointestinal malignancies. Lesions were identified for early and late response scans. VOI were drawn independently on all scans using an adaptive 50% threshold method (A50). In addition, various types of (non-)rigid image registration were applied to PET and/or CT images, after which baseline VOI were projected onto response scans. Response was classified using PET Response Criteria in Solid Tumors for maximum standardized uptake value (SUV(max)), average SUV (SUV(mean)), peak SUV (SUV(peak)), metabolically active tumour volume (MATV), total lesion glycolysis (TLG) and the area under a cumulative SUV-volume histogram curve (AUC). RESULTS Non-rigid PET-based registration and non-rigid CT-based registration followed by non-rigid PET-based registration (CTPET) did not show differences in response classifications compared to A50 for SUV(max) and SUV(peak), however, differences were observed for MATV, SUV(mean), TLG and AUC. For the latter, these registrations demonstrated a poorer performance for small lung lesions (<2.8 ml), whereas A50 showed a poorer performance when another area with high uptake was close to the target lesion. All methods were affected by lesions with very heterogeneous tracer uptake. CONCLUSIONS Non-rigid PET- and CTPET-based image registrations may be used to classify response based on SUV(max) and SUV(peak). For other quantitative measures future studies should assess which method is valid for response evaluations by correlating with survival data.
منابع مشابه
Effects of rigid and non-rigid image registration on test-retest variability of quantitative [18F]FDG PET/CT studies
BACKGROUND [18F]fluoro-2-deoxy-D-glucose ([18F]FDG) positron emission tomography (PET) is a valuable tool for monitoring response to therapy in oncology. In longitudinal studies, however, patients are not scanned in exactly the same position. Rigid and non-rigid image registration can be applied in order to reuse baseline volumes of interest (VOI) on consecutive studies of the same patient. The...
متن کاملDetection of Alzheimer\\\\\\\'s Disease using Multitracer Positron Emission Tomography Imaging
Alzheimer's disease is characterized by impaired glucose metabolism and demonstration of amyloid plaques. Individual positron emission tomography tracers may reveal specific signs of pathology that is not readily apparent on inspection of another one. Combination of multitracer positron emission tomography imaging yields promising results. In this paper, 57 Alzheimer's disease neuroimaging ini...
متن کاملEffects of rigid and non-rigid image registration on test-retest variability of quantitative [F]FDG PET/CT studies
Background: [F]fluoro-2-deoxy-D-glucose ([F]FDG) positron emission tomography (PET) is a valuable tool for monitoring response to therapy in oncology. In longitudinal studies, however, patients are not scanned in exactly the same position. Rigid and non-rigid image registration can be applied in order to reuse baseline volumes of interest (VOI) on consecutive studies of the same patient. The pu...
متن کاملBackground-Based Delineation of Internal Tumor Volumes on Static Positron Emission Tomography in a Phantom Study
Objective(s): Considering the fact that the standardized uptake value (SUV) of a normal lung tissue is expressed as x±SD, x+3×SD could be considered as the threshold value to outline the internal tumor volume (ITV) of a lung neoplasm. Methods: Three hollow models were filled with 55.0 kBq/mL fluorine18- fluorodeoxyglucose (18F-FDG) to represent tumors. The models were fixed to a barrel filled w...
متن کاملPredictive ability of 18F-fluorodeoxyglucose positron emission tomography/computed tomography for pathological complete response and prognosis after neoadjuvant chemotherapy in triple-negative breast cancer patients
Objective The mortality of patients with locally advanced triple-negative breast cancer (TNBC) is high, and pathological complete response (pCR) to neoadjuvant chemotherapy (NAC) is associated with improved prognosis. This retrospective study was designed and powered to investigate the ability of 18F-fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) to predict pat...
متن کامل