Pars plana Ahmed valve implant and vitrectomy in the management of neovascular glaucoma.

نویسندگان

  • Hooshang Faghihi
  • Fedra Hajizadeh
  • Seyed-Farzad Mohammadi
  • Arezoo Kadkhoda
  • Gholam A Peyman
  • Mohammad Riazi-Esfahani
چکیده

BACKGROUND AND OBJECTIVE To evaluate the efficacy and safety of the pars plana Ahmed glaucoma valve (New World Medical, Inc., Rancho Cucamonga, CA) implant combined with pars plana vitrectomy and panretinal photocoagulation for the management of neovascular glaucoma in patients with vitreous hemorrhage. PATIENTS AND METHODS The records of 18 eyes of 17 consecutive patients with neovascular glaucoma who had undergone pars plana vitrectomy and pars plana Ahmed valve implant were evaluated. The patients were observed for a mean time of 14.2 months (range, 6 to 28 months). RESULTS Mean preoperative intraocular pressure with oral and two or three topical antiglaucoma medications was 53.3 +/- 10 mm Hg, and mean postoperative intraocular pressure without oral antiglaucoma medications was 16.3 +/- 7.1 mm Hg (P < .0001) at the final visit. Overall success rate was 72.2%, defined as an intraocular pressure of 5 to 21 mm Hg with or without antiglaucoma medication. A postoperative hypertensive phase occurred in 7 patients (38.8%), of which all but one responded to medical therapy. Visual acuity was stabilized or improved in 77.7% of the eyes. There was one case of each of the following adverse events: mild vitreous cavity hemorrhage, hypotony, choroidal effusion, epiretinal membrane, corneal edema, and corneal ulcer. Two cases developed phthisis bulbi and lost light perception. CONCLUSIONS Pars plana vitrectomy and Ahmed valve implantation seems to be a viable surgical modality in the management of neovascular glaucoma and coexisting posterior segment pathology with a relatively low rate of serious permanent postoperative complications.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pars Plana Ahmed Implantation Combined with 23-gauge Vitrectomy for Refractory Neovascular Glaucoma in Diabetic Retinopathy

PURPOSE To evaluate the efficacy and safety of a pars plana Ahmed valve implantation combined with 23-gauge sutureless vitrectomy in the treatment of patients with medically uncontrolled neovascular glaucoma (NVG) in proliferative diabetic retinopathy (PDR). METHODS The authors retrospectively reviewed the records of 11 consecutive patients with refractory NVG in PDR who underwent a 23-gauge ...

متن کامل

Case-matched comparison of vitrectomy, peripheral retinal endolaser, and endocyclophotocoagulation versus standard care in neovascular glaucoma.

PURPOSE To evaluate the efficacy of combination pars plana vitrectomy, endoscopic peripheral panretinal photocoagulation, and endocyclophotocoagulation (ECP) as compared with standard care in patients with neovascular glaucoma. METHODS This age-matched case-controlled retrospective series of 54 eyes compared the clinical outcomes between a consecutive series of combination pars plana vitrecto...

متن کامل

Intraocular lens dislocation and tube shunt in the posterior chamber: a case report

BACKGROUND To describe management of a case of intraocular lens (IOL) and capsular bag (CB) dislocation in an eye with an Ahmed glaucoma valve in the posterior chamber. CASE PRESENTATION A 75-year-old pseudophakic man with open-angle glaucoma and diabetic retinopathy developed neovascular glaucoma. After two intravitreous injections of bevacizumab and panretinal photocoagulation were administ...

متن کامل

[Simultaneous pars plana vitrectomy and glaucoma drainage device implant].

PURPOSE To evaluate intraocular pressure (IOP) and visual acuity (VA) results after glaucoma drainage device (GDD) implantation combined with simultaneous pars plana vitrectomy (PPV). MATERIAL AND METHODS Retrospective review of 8 eyes (7 patients). The diagnosis was neovascular glaucoma (NVG) secondary to proliferative diabetic retinopathy in 4 eyes, in a which a double plate Molteno implant...

متن کامل

Efficacy and safety of the pars plana clip in the Ahmed valve device inserted via the pars plana in patients with refractory glaucoma

PURPOSE To evaluate the efficacy and safety of the pars plana clip (PPC) in the Ahmed valve tube inserted via the pars plana in patients with secondary refractory glaucomas. METHODS Prospective and interventional case series that included 10 patients with secondary refractory glaucoma. The pars plana vitrectomy and the implant of the modified tube were performed during the same surgery. Contr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ophthalmic surgery, lasers & imaging : the official journal of the International Society for Imaging in the Eye

دوره 38 4  شماره 

صفحات  -

تاریخ انتشار 2007