Percutaneous Pedicle Screw Fixation of a Hangman's Fracture Using Intraoperative, Full Rotation, Three-dimensional Image (O-arm)-based Navigation: A Technical Case Report
نویسندگان
چکیده
Surgical treatment of a hangman's fractures is technically demanding, even when using the standard open procedure. In this case report, a type II hangman's fracture was treated by percutaneous posterior screw fixation, without a midline incision, using intraoperative, full rotation, three-dimensional (3D) image (O-arm)-based navigation. A 48-year-old woman was injured in a motor vehicle accident and diagnosed with a unilateral hangman's fracture associated with subluxation of the C2 vertebral body on C3. After attaching the reference arc of the 3D-imaging system to the headholder, the cervical spine was screened using an O-arm without anatomical registration. Drilling and screw fixation were performed using a guide tube while referring to the reconstructed 3D-anatomical views. The operation was successfully completed without technical difficulties or neurovascular complications. This percutaneous procedure requires less dissection of normal tissue, which may allow earlier recovery. However, further validation of this procedure for its effectiveness and safety is required.
منابع مشابه
Transpedicular wedge osteotomy for treatment of kyphosis after L1 fracture using intraoperative, full rotation, three-dimensional image (O-arm)-based navigation: a case report.
There has been a large series in the literature reporting on results of osteotomy for the correction of kyphotic deformity secondary to post-traumatic thoracolumbar fracture. However, there are few reports on using intraoperative, full rotation, three dimensional image (O-arm)-based navigation, transpedicular wedge osteotomy for the correction of kyphotic deformity in old thoracolumbar fracture...
متن کاملIntra-operative Iso-C3D navigation for pedicle screw instrumentation of hangman's fracture: a case report.
Pedicle screw instrumentation of the upper cervical spine is rarely performed in trauma surgery because of the risk of damaging neurovascular structures. We report successful treatment of an unstable hangman's fracture with posterior pedicle screw fixation using Iso-C3D fluoroscopy-based computer navigation guidance. Postoperative computed tomographic images confirmed accurate placement of the ...
متن کاملCommentary: Utility of the O-Arm in spinal surgery
BACKGROUND More studies report the intraoperative benefits vs. risks of utilizing the O-Arm in performing pedicle screw insertion in spinal surgery. METHODS/RESULTS Several studies document the utility of CT-guided O-arm placement of pedicle/lateral mass screws. Singh et al. documented the efficacy of CT guided-O Arm placement of pedicle screws and lateral mass screws in the upper cervical sp...
متن کاملComplication Avoidance and Management Using the O-arm for Odontoid Screw Fixation: Technical Note
Objective: Odontoid screw fixation is an accepted surgical approach for Type 2 odontoid fractures with an intact transverse ligament. Typically, intraoperative bi-planar flouroscopy is used for placement of an odontoid screw. However, the quality of the images obtained with bi-planar fluoroscopy in the operating room is variable (due to patient body habitus) and screws may be misplaced. We repo...
متن کاملOne-stage posterior C2 and C3 pedicle screw fixation or combined anterior C2-C3 fusion for the treatment of unstable hangman’s fracture
The present study aimed to evaluate the effect of using one-stage posterior C2 and C3 pedicle screw fixation or combined anterior C2-C3 fusion in the treatment of unstable hangman's fracture. A total of 13 patients with unstable hangman's fractures underwent C2 and C3 pedicle screw fixation, lamina interbody fusion or combined anterior C2-C3 fusion and imaging examinations to evaluate the fract...
متن کامل