Thermal Management in High-Density Power Converters

نویسنده

  • Martin März
چکیده

This paper gives an overview of basic principles of the thermal management in high density power converters. Methods for heat removal on a device and circuit board level are discussed. New packaging technologies for discrete power semiconductors as well as multifunctional board integration techniques are included. A view is given on future 3D integration techniques that take into account the poor thermal conductivity especially of the passive component materials. With these techniques much higher power densities are possible. Some examples of prototype systems are presented, together with the achieved technical data.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Chapter 4 . High Frequency LLC Resonant Converter

With the development of power conversion technology, power density becomes the major challenge for front-end AC/DC converters. Although increasing switching frequency can dramatically reduce the passive component size, its effectiveness is limited by the converter efficiency and thermal management. In present industry implementations, due to the low efficiency PWM type topologies, DC/DC stage s...

متن کامل

Soft-Switching performance of Dual Active Bridge DC-DC Converter

This paper presents the Zero-Voltage Switching (ZVS) performance of Dual Active Bridge (DAB) DC-DC converter for high power density aerospace applications. Switching transitions of the transistor occurring in favorable conditions such as device zero-voltage or zero-current is called as soft-switching. The benefits of soft-switching are reduced switching losses, switch stress, low electromagneti...

متن کامل

Thermal Power Density Barriers of Converter Systems

With the desire to integrate power converters into larger systems, high power density became a very important issue. In this paper we discuss the thermal limits of the power density of converter systems. It is shown that these limits are partly given by today’s technology and partly given by physics. Employing the given equations, one can quickly estimate the maximum possible power density of a...

متن کامل

Conduction and Dead-Time Voltage Drops Estimation of Asymmetric Cascaded H-Bridge Converters Utilizing Level-Shifted PWM Scheme

Linear AC power supplies can be replaced by their nonlinear switching counterparts due to the lower voltage drops and higher efficiency and power density of switching-mode inverters. Multilevel cascaded H-bridge (CHB) converters are the preferred inverter structure because of modular configuration, control, and protection. The output voltage quality in CHB converters depends on the number of ou...

متن کامل

Passivity-Based Control of the DC-DC Buck Converters in High-Power Applications

In this paper, a novel approach for control of the DC-DC buck converter in high-power and low-voltage applications is proposed. Designed method is developed according to passivity based controller which is able to stabilize output voltage in a wide range of operation. It is clear that in high-power applications, parasitic elements of the converter may become comparable with load value and hence...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003