Development of a light-weight portable neutron survey meter.

نویسندگان

  • Tomoya Nunomiya
  • Takashi Nakamura
  • Tetsuo Koyama
  • Daisuke Inui
  • Takeshi Ishikura
چکیده

A light-weight portable neutron survey meter was developed using a mixed organic gas counter for dose management at nuclear power plants and accelerator facilities. This survey meter, NSN31041, is ~2 kg in weight and W160×H250×L300 mm(3) in size, which is capable of measuring neutron ambient dose equivalent rate from thermal to 15 MeV neutrons. The neutron energy response of the survey meter is evaluated using continuous energy neutron sources of (252)Cf, (241)Am-Be, thermal neutrons generated from a graphite pile loading a (252)Cf source, concrete-moderated neutrons of (241)Am-Be source and D(2)O-moderated neutrons of (252)Cf source. The measured response data show very good agreement with neutron ambient dose equivalent within a 50 % deviation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The comparison between simple and advanced shielding materials for the shield of portable neutron sources

Background: Monte Carlo simulations play a vital role in the calculation of the necessary shielding both for neutrons and photons. Advanced and simple shielding materials against neutron and gamma rays were compared by simulation using the MCNB4B Monte Carlo code. The simulations were carried out for the three common neutron sources, namely the 252Cf, the 241Am/Be and the DD neutron generator w...

متن کامل

An accurate and portable solid state neutron rem meter

Accurately resolving the ambient neutron dose equivalent spanning the thermal to 15 MeV energy range with a single configuration and lightweight instrument is desirable. This paper presents the design of a portable, high intrinsic efficiency, and accurate neutron rem meter whose energy-dependent response is electronically adjusted to a chosen neutron dose equivalent standard. The instrument may...

متن کامل

Title Design of light element analysis system in BNCT and every NCT

Introduction: The Monte Carlo simulation is used to enhance reliability in the experiments related to nuclear instruments. in addition, that is used to calculate the different components of the neutron and gamma ray fluxes in boron neutron capture therapy(BNCT) and neutron capture (NCT)applications. BNCT is one of the methods in radiotherapy, that is used the neutron beam for ki...

متن کامل

Development and test of a GEM-based TEPC for neutron protection dosimetry.

A novel tissue-equivalent proportional counter (TEPC) based on a gas electron multiplier (GEM) for measuring H*(10) for neutrons was designed and constructed. The pulse height spectra (PHS) of two different neutron sources (a 252Cf source and a AmBe source) were measured using the new TEPC. The measurements were made with the TEPC filled with two different gases (10P gas and a propane-based tis...

متن کامل

Microbial quality of drinking water of Bandar Abbas’ buses

Introduction: Finding the importance of safe water, developed countries, have solved many of their health problems. In Iran, as there are not enough regular available and railways and airways, buses are the main way for transportation. Pollution of drinking water in those buses is a serious way for spreading waterborne diseases. This survey has been conducted to assess the quality of drinking...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiation protection dosimetry

دوره 146 1-3  شماره 

صفحات  -

تاریخ انتشار 2011