Patient‐specific independent 3D GammaPlan quality assurance for Gamma Knife Perfexion radiosurgery
نویسندگان
چکیده
One of the most important aspects of quality assurance (QA) in radiation therapy is redundancy of patient treatment dose calculation. This work is focused on the patient-specific time and 3D dose treatment plan verification for stereotactic radiosurgery using Leksell Gamma Knife Perfexion (LGK PFX). The virtual model of LGK PFX was developed in MATLAB, based on the physical dimensions provided by the manufacturer. The ring-specific linear attenuation coefficients (LAC) and output factors (OFs) reported by the manufacturer were replaced by the measurement-based collimator size-specific OFs and a single LAC = 0.0065 mm-1. Calculation depths for each LGK PFX shot were obtained by ray-tracing technique, and the dose calculation formalism was similar to the one used by GammaPlan treatment planning software versions 8 and 9. The architecture of the QA process was based on the in-house online database search of the LGK PFX database search for plan-specific information. A series of QA phantom plans was examined to verify geometric and dosimetric accuracy of the software. The accuracy of the QA process was further evaluated through evaluation of a series of patient plans. The shot time/focus point dose verification for each shot took less than 1 sec/shot with full 3D isodose verification taking about 30 sec/shot on a desktop PC. GammaPlan database access time took less than 0.05 sec. The geometric accuracy (location of the point of maximum dose) of the phantom and patient plan was dependent on the resolution of the original dose matrix and was of the order of 1 dose element. Dosimetric accuracy of the independently calculated phantom and patient point (focus) doses was within 3.5% from the GammaPlan, with the mean = 2.3% and SD= 1.1%. The process for independent pretreatment patient-specific Gamma Knife Perfexion time and dose verification was created and validated.
منابع مشابه
Two‐year experience with the commercial Gamma Knife Check software
The Gamma Knife Check software is an FDA approved second check system for dose calculations in Gamma Knife radiosurgery. The purpose of this study was to evaluate the accuracy and the stability of the commercial software package as a tool for independent dose verification. The Gamma Knife Check software version 8.4 was commissioned for a Leksell Gamma Knife Perfexion and a 4C unit at the Univer...
متن کاملGammaPlan-Leksell Gamma Knife radiosurgery treatment planning verification method.
This work provides a method for an independent check of Gamma Knife GammaPlan radiosurgery calculations, named the spherical approximation method or SAM. Based on skull dimension measurements, the treated volume of the head is modeled as a sphere of radius R. With this approximation, an analytical solution for fast ray tracing of the path length, for each of the 201 beamlets, of the Gamma Knife...
متن کاملFailure modes and effects analysis (FMEA) for Gamma Knife radiosurgery
PURPOSE Gamma Knife radiosurgery is a highly precise and accurate treatment technique for treating brain diseases with low risk of serious error that nevertheless could potentially be reduced. We applied the AAPM Task Group 100 recommended failure modes and effects analysis (FMEA) tool to develop a risk-based quality management program for Gamma Knife radiosurgery. METHODS A team consisting o...
متن کاملClinical Application of 7.0 T Magnetic Resonance Images in Gamma Knife Radiosurgery for a Patient with Brain Metastases
In the study we assessed the distortion of 7.0 T magnetic resonance (MR) images in reference to 1.5 T MR images in the radiosurgery of metastatic brain tumors. Radiosurgery with Gamma Knife Perfexion was performed for the treatment of a 54-yr-old female patient with multiple brain metastases by the co-registered images of the 7.0 T and 1.5 T magnetic resonance images (MRI). There was no signifi...
متن کاملEffective usage of a clearance check to avoid a collision in Gamma Knife Perfexion radiosurgery with the Leksell skull frame
Skull frame attachment is one of the most significant issues with Gamma Knife radiosurgery. Because of the potential for suffering by patients, careful control of the frame position is required to avoid circumstances such as collision between the frame or the patient's head and the collimator helmet, and inaccessible target coordinates. This study sought to develop a simulation method to find t...
متن کامل