Beam Tilt Signals as Emittance Diagnostic in the Next Linear Collider Main Linac
نویسندگان
چکیده
High frequency cavity beam position monitors (BPMs) can also provide information on the xz or yz correlation of the beam (yaw or pitch, respectively). Such a diagnostic is particularly desirable in the Next Linear Collider (NLC) main linacs, where the principal sources of emittance dilution generate such a correlation. Test results from the extremely low emittance beam at the KEK Accelerator Test Facility (ATF) [1] are described. The formalism of beam-tilt signal generation and detection are reviewed, and studies of possible emittance correction schemes based on the beam tilt signals are presented. Presented at 2002 European Particle Accelerator Conference, Paris, France, June 3 – June 7, 2002. * Work Supported by the U.S. Department of Energy, Contract DE-AC03-76SF00515. BEAM TILT SIGNALS AS EMITTANCE DIAGNOSTIC IN THE NEXT LINEAR COLLIDER MAIN LINAC * P. Tenenbaum, J. Frisch, D. McCormick, M. Ross, S. Smith, SLAC, Stanford, CA, USA
منابع مشابه
Developments in Beam-based Alignment and Steering of the next Linear Collider Main Linac
The Next Linear Collider main linacs are 13 km linear accelerators which each contain approximately 750 hybrid iron/permanent-magnet quadrupoles in a FODO array. The small amount of vertical emittance dilution permitted in the main linacs implies a tight tolerance on the RMS distance between the beam and the centers of the quads. We describe two methods for measuring the offsets between the qua...
متن کاملQuadrupole Centering and Beam Steering in the next Linear Collider Main Linacs
Accurate measurement of quadrupole-to-BPM center offsets and use of this information in an auto-steering algorithm are two essential components of emittance preservation in the Next Linear Collider main linac. We present the results of an analytic/simulation study of possible statistical and systematic limitations on the measurement of quad-BPM center offsets. These results are incorporated in ...
متن کاملQuadrupole Centering and Beam Steering in the Next Linear Collider Main Linacs1
Accurate measurement of quadrupole-to-BPM center offsets and use of this information in an autosteering algorithm are two essential components of emittance preservation in the Next Linear Collider main linac. We present the results of an analytic/simulation study of possible statistical and systematic limitations on the measurement of quad-BPM center offsets. These results are incorporated in a...
متن کاملMain Linac Single Bunch Emittance Preservation in the NLC and USColdLC Configurations
We consider the emittance preservation issues in two possible linear collider main linac configurations: The Next Linear Collider (NLC), using 11.424 GHz copper accelerating structures at a loaded gradient of 52 MeV/meter, and USColdLC, using 1.3 GHz superconducting structures at a loaded gradient of 28 MeV/meter. Emittance dilution sources considered include misalignments of individual element...
متن کاملEmittance-imposed Alignment and Frequency Tolerances for the Tesla Linear Collider
One option in building a future 500 GeV c.m. linear collider is to use superconducting 1.3 GHz 9-cell cavities. However, wakefields excited by the bunch train in the TESLA (TeV-Energy Super Conducting Linear Accelerator) collider can resonantly drive the beam into unstable operation such that a BBU (Beam Break Up) mode results or at the very least significant emittance dilution occurs. The larg...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2002