Subthreshold 577 nm micropulse laser treatment for central serous chorioretinopathy
نویسندگان
چکیده
PURPOSE To compare the efficacy of the subthreshold micropulse laser (SML) to conventional laser (CL) in treating focal leakages of the retinal pigment epithelium (RPE) in the eyes with central serous chorioretinopathy (CSC). METHODS Twenty-nine eyes of 28 patients with CSC and typical focal leakage were treated with CL or SML. Both treatments were made with a 577 nm yellow laser (CL: NIDEK MC-500, SML: IRIDEX IQ577). The percentage of eyes with a complete resolution, the distance of the laser burns from the fovea, and injury of the RPE after treatment were studied. RESULTS A complete resolution was seen in 10 of 15 eyes (66.7%) after CL and 9 of 14 eyes (64.3%) after SML (P = 0.89). The average distance from the foveal center to the leakage point was 1282±596 μm for eyes treated with CL and 1271±993 μm for eyes treated with SML (P = 0.4). Only three eyes treated with SML had treatment sites within 500 μm of the fovea. RPE damage determined by fundus autofluorescence was found in all eyes treated with CL and only one eye treated with SML (P<.01). CONCLUSIONS SML achieved equivalent therapeutic effects as CL but without RPE damage in eyes with CSC.
منابع مشابه
Subthreshold micropulse yellow laser treatment for nonresolving central serous chorioretinopathy.
PURPOSE To report the efficacy and safety of micropulse 577 nm yellow laser in the treatment of nonresolving central serous chorioretinopathy (CSC) cases. PATIENTS AND METHODS The study included 15 eyes with nonresolving CSC lasting more than 3 months. All the patients were subjected to complete ophthalmic examination, in addition to contrast sensitivity measurement, fundus fluorescein angiog...
متن کاملSubthreshold Micropulse Laser (577 nm) Treatment in Chronic Central Serous Chorioretinopathy.
PURPOSE To assess treatment with a 577-nm subthreshold micropulse laser (SML) in patients with chronic central serous chorioretinopathy (cCSC). METHODS This retrospective study included 38 patients treated with a 577-nm SML (Supra Scan; Quantel Medical) for cCSC. We included a subgroup of 18 patients with persistent subretinal fluid (SRF) after photodynamic therapy (PDT). Assessment included ...
متن کاملA Review of Subthreshold Micropulse Laser for Treatment of Macular Disorders
Micropulse laser treatment is an alternative to the conventional continuous-wave laser for the treatment of retinal or macular diseases. In contrast to the conventional laser, the therapeutic effect of the subthreshold micropulse laser is not accompanied by thermal retinal damage. This fact is of particular importance when a treatment near the fovea is required. Micropulse treatment is applied ...
متن کاملIncrease in Central Retinal Edema after Subthreshold Diode Micropulse Laser Treatment of Chronic Central Serous Chorioretinopathy
UNLABELLED Purpose. Subthreshold diode micropulse laser (SDM) treatment is believed to be safe method of treating clinical entities involving retinal edema. We present a case of serous edematous reaction of the retina to SDM treatment. Methods. CASE REPORT Results. A patient with chronic central serous chorioretinopathy (CSCR) was treated with SDM Yellow multispot laser. Procedure had been pr...
متن کاملLow-intensity/high-density Subthreshold Diode Micropulse Laser for Central Serous Chorioretinopathy.
PURPOSE To review the results of low-intensity/high-density subthreshold micropulse laser (SDM) for treatment of central serous chorioretinopathy. METHOD The records of all patients treated in a retinal subspecialty practice with SDM for central serous chorioretinopathy were reviewed. RESULTS Eleven consecutive eyes of 11 patients treated between October 2011 and April 2014 were identified ...
متن کامل