Tympanometry in Infants: A Study of the Sensitivity and Specificity of 226-Hz and 1,000-Hz Probe Tones
نویسندگان
چکیده
Introduction For infants under 6 months, the literature recommends 1,000-Hz tympanometry, which has a greater sensitivity for the correct identification of middle ear disorders in this population. Objective To systematically analyze national and international publications found in electronic databases that used tympanometry with 226-Hz and 1,000-Hz probe tones. Data Synthesis Initially, we identified 36 articles in the SciELO database, 11 in the Latin American and Caribbean Literature on the Health Sciences (LILACS) database, 199 in MEDLINE, 0 in the Cochrane database, 16 in ISI Web of Knowledge, and 185 in the Scopus database. We excluded 433 articles because they did not fit the selection criteria, leaving 14 publications that were analyzed in their entirety. Conclusions The 1,000-Hz tone test has greater sensitivity and specificity for the correct identification of tympanometric curve changes. However, it is necessary to clarify the doubts that still exist regarding the use of this test frequency. Improved methods for rating curves, standardization of normality criteria, and the types of curves found in infants should be addressed.
منابع مشابه
Accoustic immitance measures in infants with 226 and 1000 hz probes : correlation with otoacoustic emissions and otoscopy examination Summary
Audi ological evaluation in infants should include the middle ear (immitance measures and otoscopy) and also a cochlear evaluation. Aim: To check which tympanometry tone test (226 Hz or 1000 Hz), transient otoacoustic emissions and otoscopy. Methods: Transient otoacoustic emissions were taken from sixty infants ranging from zero to four months of age. The babies were assigned to two groups of 3...
متن کاملAccoustic immitance measures in infants with 226 and 1000 hz probes: correlation with otoacoustic emissions and otoscopy examination.
UNLABELLED Audiological evaluation in infants should include the middle ear (immitance measures and otoscopy) and also a cochlear evaluation. AIM To check which tympanometry tone test (226 Hz or 1000 Hz), transient otoacoustic emissions and otoscopy. METHODS Transient otoacoustic emissions were taken from sixty infants ranging from zero to four months of age. The babies were assigned to two...
متن کاملTympanometry with 226 and 1000 Hertz tone probes in infants.
UNLABELLED This study aimed at describing and analyzing tympanometric results obtained with 226 Hz and 1000 Hz probe tones; checking for correlations between tympanometry, otoacoustic emissions and otoscopic examination; describing abnormal results found in the evaluation procedures. METHODS Double-blind and prospective study. Our sample included 70 babies, between 7 days and one month and 13...
متن کاملMultifrequency tympanometry in infants
INTRODUCTION The use of conventional tympanometry is not sufficiently sensitive to detect all cases of middle ear changes, and this hinders accurate diagnosis. OBJECTIVE To characterize acoustic immittance measures of infants from 0 to 3 months of age using multifrequency tympanometry in a prospective study. METHOD 54 infants from 0 to 3 months of age were evaluated. The inclusion criter...
متن کاملAcoustic reflex on newborns: the influence of the 226 and 1,000 Hz probes.
PURPOSE To analyze the occurrence of acoustic reflex and its threshold on newborns using the 226 and 1,000 Hz probes. METHODS Thirty-six newborns with "PASS" results in newborn hearing screening and tympanogram with one or two peaks for both probe tones were included. Group I comprised 20 full-term newborns without risk indicator for hearing loss, and Group II comprised 16 newborns with at le...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 17 شماره
صفحات -
تاریخ انتشار 2013