REPLACE DARE (Death After Replacement Evaluation) score: determinants of all-cause mortality after implantable device replacement or upgrade from the REPLACE registry.
نویسندگان
چکیده
BACKGROUND Identifying factors predictive of mortality may be important to decrease risk associated with cardiac implantable electrical device (CIED) replacement procedures. This study aimed to determine whether clinical factors and complications independently associate with death and to develop a mortality risk prediction tool after CIED replacement. METHODS AND RESULTS The prospective REPLACE Registry determined 6-month complication and mortality rates after CIED replacement with or without planned lead addition or revision. Vital status was collected. Kaplan-Meier survival and multivariable Cox proportional hazards regression analyses were performed to identify patient, procedural, or complication variables predictive of death. The REPLACE DARE (Death After Replacement Evaluation) Score was constructed using hazard ratios, reflecting relative risk contributions of each variable, combined into an additive mortality risk score equation. At 6 months, 70 of 1744 (4.0%) patients had died. Cox regression analysis found no significant association between major complications and death. However, recent heart failure admission, New York Heart Association class III/IV, antiarrhythmic drug use, cerebrovascular disease, and chronic kidney disease stage were independently associated with 6-month mortality. The REPLACE DARE Score was 2.0±1.4 in survivors versus 3.5±1.8 in nonsurvivors (P<0.001), with predictive receiver operating characteristic value=0.758 (P<0.001). Risk of death was 1.0% for DARE=0 and 55.6% for DARE=7. The hazard ratio was 1.8 for each change of 1 DARE unit. CONCLUSIONS Comorbidities, but not complications, were significantly associated with mortality after CIED replacement. The REPLACE DARE Score is a novel tool that can identify patients with substantial mortality risk. Such patients should have the relative risk and benefit of their procedure considered carefully. CLINICAL TRIAL REGISTRATION URL http://www.clinicaltrials.gov. Unique identifier: NCT00395447.
منابع مشابه
Response to Letter Regarding "REPLACE DARE (Death After Replacement Evaluation) Score: Determinants of All-Cause Mortality After Implantable Device Replacement Or Upgrade From the REPLACE Registry".
Response to Letter Regarding “REPLACE DARE (Death After Replacement Evaluation) Score: Determinants of All-Cause Mortality After Implantable Device Replacement Or Upgrade From the REPLACE Registry” We were pleased to see the results of the validation work done by Barra et al in examining the performance of the REPLACE (Death After Replacement Evaluation) DARE score in their patient population. ...
متن کاملThe REPLACE Death after replacement evaluation score for predicting mortality after device replacement or upgrade: should all implantable devices be replaced?
متن کامل
Replacement of dietary fish meal with plant sources in rainbow trout (Oncorhynchus mykiss) effect on growth performance, immune responses, blood indices and disease resistance
The aim of this study was to examine the effects of replacing fish meal with plant sources on growth performance, immune responses, hematological parameters and disease resistance in rainbow trout. In this study, mean of initial body weight of fish was 15±2 g and the experiment was carried out for a period of 60 days. Four experimental diets were formulated to replace 0, 40, 70 and 100% fish me...
متن کاملArrhythmia/Electrophysiology Complication Rates Associated With Pacemaker or Implantable Cardioverter-Defibrillator Generator Replacements and Upgrade Procedures Results From the REPLACE Registry
Background—Prospective studies defining the risk associated with pacemaker or implantable cardioverter-defibrillator replacement surgeries do not exist. These procedures are generally considered low risk despite results from recent retrospective series reporting higher rates. Methods and Results—We prospectively assessed predefined procedure-related complication rates associated with elective p...
متن کاملComplication rates associated with pacemaker or implantable cardioverter-defibrillator generator replacements and upgrade procedures: results from the REPLACE registry.
BACKGROUND Prospective studies defining the risk associated with pacemaker or implantable cardioverter-defibrillator replacement surgeries do not exist. These procedures are generally considered low risk despite results from recent retrospective series reporting higher rates. METHODS AND RESULTS We prospectively assessed predefined procedure-related complication rates associated with elective...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation. Arrhythmia and electrophysiology
دوره 7 6 شماره
صفحات -
تاریخ انتشار 2014