Assessment of Patient Dose in CT

نویسنده

  • P C Shrimpton
چکیده

This report summarises work undertaken in support of a European Commission (EC) Concerted Action on CT that has included both a review and further development of the framework for CT dosimetry. The system previously established by the EC for reference doses in CT (with the quantities weighted CTDI (CTDIw) and dose-length product (DLP)) has been expanded to include subsequent developments in CT technology, such as multi-slice scanners and the recommendation for display of volume CTDI (CTDIvol) on the scanner console. New Monte Carlo calculations for CT have been carried out to supplement the relative lack of normalised organ dose data available for paediatric patients. Series of simulations have been completed for 3 particular models of scanner and 6 mathematical phantoms representing ages newborn, 1y, 5y, 10y, 15y and adult. Analysis of these results has confirmed the trends for an enhancement of the doses to small children relative to those to adults under similar conditions of CT exposure, by factors up to 2.6 in the case of the newborn patient, depending on scanner model and region of scan. A new comprehensive framework is proposed for assessing organ doses in CT based on coefficients relating them to corresponding values of CTDIw in the standard (head or body) CT dosimetry phantoms. This approach would potentially provide a single set of dose coefficients for each standard patient age for universal application to all scanner models. Some initial values are presented of effective dose normalised both to CTDIw and DLP for combinations of standard examination and phantom age. This study was partially funded by the European Commission under Contract No FIGM-CT2000-2078. © National Radiological Protection Board Chilton Didcot Oxon OX11 0RQ Approval: March 2004 Publication: March 2004 This NRPB report reflects understanding and evaluation of the current scientific evidence as presented and referenced in this document. ASSESSMENT OF PATIENT DOSE IN CT

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of Patient Dose from CT Examinations in Khorasan, Iran

Introduction Computed Tomography scans are a very important tool for diagnosis and assessment of response to treatment in the practice of medicine. Ionizing radiation in medical imaging is undoubtedly one of the most powerful diagnostic tools in medicine. Yet, as with all medical interventions, there are potential risks in addition to the clear potential benefits. Materials and Methods Two refe...

متن کامل

Assessment and evaluation of patient doses in adult common CT examinations towards establishing national diagnostic reference levels

Background: Patient radiation doses from computed tomography (CT) are increasing due to the number of CT examinations performed every day. The aim of this study was assess and evaluate patient radiation doses for adult’s common CT examinations to derive local diagnostic guidance levels for common CT examinations. Materials and Methods: Volume and weighted computed tomography dose index (C...

متن کامل

Assessment of dose reduction and influence of gantry rotation time in CT abdomen examinations

Background: Worldwide the computed tomography (CT) scanning is recognized as a high radiation dose modality. This article aimed to estimate the radiation dose reduction and radiogenic risks for adult patients undertaking abdominal CT examinations. Materials and Methods: A total of 128 patients were studied using 2, 4, 16 and 64 slice CT scanners. The patients were divided into two categories: t...

متن کامل

Dose Assessment in Computed Tomography Examination and Establishment of Local Diagnostic Reference Levels in Mazandaran, Iran

Background: Medical X-rays are the largest man-made source of public exposure to ionizing radiation. While the benefits of Computed Tomography (CT) are well known in accurate diagnosis, those benefits are not risk-free. CT is a device with higher patient dose in comparison with other conventional radiation procedures. Objective: This study is aimed at evaluating radiation dose to patients from ...

متن کامل

Patient-Specific Radiation Dose and Cancer Risk in Computed Tomography Examinations in Ondo, Nigeria

Introduction: The dose in computed tomography (CT) often approach or exceed the optimum levels, thereby increasing the probability of cancer induction. With wide application of this diagnostic test, it is expedient to determine the effective dose (ED) for each patient to estimate their cancer risk. This study was conducted to investigate the patient-specific dose (PSD) and cancer risk in CT exa...

متن کامل

A New Method for Estimating of Patient Effective Dose in Computed Tomography Based on Body Mass Index: Performance of the Method in Abdomen-Pelvic Examination

Introduction: The CT Provide high quality images, especially in low-contrast soft tissue, are another advantage. Along with all the benefits that the CT scans which have, the patient dose of this modality is much greater than other methods. As a result, medical imaging community must ensure that the benefits of radiological examination for each patient are higher than related r...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004