Regional annulus fibre orientations used as a tool for the calibration of lumbar intervertebral disc finite element models.

نویسندگان

  • Andrea Malandrino
  • Jérôme Noailly
  • Damien Lacroix
چکیده

The collagen network of the annulus fibrosus largely controls the functional biomechanics of the lumbar intervertebral discs (IVDs). Quantitative anatomical examinations have shown bundle orientation patterns, possibly coming from regional adaptations of the annulus mechanics. This study aimed to show that the regional differences in annulus mechanical behaviour could be reproduced by considering only fibre orientation changes. Using the finite element method, a lumbar annulus was modelled as a poro-hyperelastic material in which fibres were represented by a direction-dependent strain energy density term. Fibre orientations were calibrated to reproduce the annulus tensile behaviours measured for four different regions: posterior outer, anterior outer, posterior inner and anterior inner. The back-calculated fibre angles and regional patterns as well as the global disc behaviour were comparable with anatomical descriptions reported in the literature. It was concluded that annulus fibre variations might be an effective tool to calibrate lumbar spine IVD and segment models.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Significance of the collagen criss-cross angle distributions in lumbar annuli fibrosi as revealed by finite element simulations

In the human lumbar spine, annulus fibrosus (AF) fibres largely contribute to intervertebral disc (IVD) stability, and detailed annulus models are required to obtain reliable predictions of lumbar spine biomechanics by finite element (FE) modelling. However, different definitions of collagen orientation coexist in the literature for healthy human lumbar AFs and are indiscriminately used in mode...

متن کامل

Estimation of spinal loads using a detailed finite element model of the L4-L5 lumbar segment derived by medical imaging kinematics; a feasibility study

Introduction: Low back pain is the most prevalent orthopedic disorder and the first main cause of poor working functionality in developed as wells as many developing countries. In Absence of noninvasive in vivo measurement approaches, biomechanical models are used to estimate mechanical loads on human joints during physical activities. To estimate joint loads via musculoskelet...

متن کامل

Patient-specific spine models. Part 1: Finite element analysis of the lumbar intervertebral disc--a material sensitivity study.

If patient-specific finite element models of the spine could be developed, they would offer enormous opportunities in the diagnosis and management of back problems. Several generic models have been developed in the past, but there has been very little detailed examination of the sensitivity of these models' characteristics to the input parameters. This relationship must be thoroughly understood...

متن کامل

Final report Geometry- and load-specific optimization of the collagen network’s fibre orientation in the lumbar spine’s annulus fibrosus

1 Abstract In Europe, low back pain (LBP) affects the quality of life of up to 30% of the active population. Although the origin of LBP is not well identified and is probably not unique, epidemiological studies suggest that the severity of the disease is correlated with mechanical factors. The lumbar spine is a complex structure where bone, cartilage, ligaments, and muscles have specific and fu...

متن کامل

Finite Element Study of a Lumbar Intervertebral Disc Nucleus Replacement Device

Nucleus replacement technologies are a minimally invasive alternative to spinal fusion and total disc replacement that have the potential to reduce pain and restore motion for patients with degenerative disc disease. Finite element modeling can be used to determine the biomechanics associated with nucleus replacement technologies. The current study focuses on a new nucleus replacement device de...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Computer methods in biomechanics and biomedical engineering

دوره 16 9  شماره 

صفحات  -

تاریخ انتشار 2013