Effect of chronic continuous positive airway pressure (CPAP) therapy on upper airway size in patients with sleep apnoea/hypopnoea syndrome.

نویسندگان

  • I L Mortimore
  • P Kochhar
  • N J Douglas
چکیده

BACKGROUND There is evidence to suggest that chronic continuous positive airway pressure (CPAP) therapy may produce reversible changes in upper airway morphology and function in patients with sleep apnoea/hypopnoea. This study was designed to examine the effect of chronic CPAP therapy on upper airway calibre. METHODS Twenty four men with the sleep apnoea/hypopnoea syndrome (mean (SE) apnoea/hypopnoea index 37 (5)) underwent lateral cephalometry with measurement of posterior airway space performed before and at least three months after initiation of CPAP therapy. RESULTS There was no weight change between the two assessments and mean CPAP use was 4.8 (0.4) hours per night. Posterior airway space (PAS) was measured in erect and supine postures. PAS supine increased with CPAP therapy from a mean (SE) of 11.8 (0.8) mm to 13.4 (0.8) mm, but PAS erect did not. Correlation of the change in PAS (dPAS) before and after CPAP therapy showed an increase with increasing CPAP compliance measured as machine run time both for dPAS supine (r = 0.68) and dPAS erect (r = 0.47). CONCLUSIONS Patients with the sleep apnoea/hypopnoea syndrome regularly using CPAP for more than four hours per night all showed an increase in dPAS supine. The use of chronic CPAP increases PAS supine probably by a reduction in upper airway oedema, and the change in size is dependent on CPAP use.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of correction of flow limitation on continuous positive airway pressure efficiency in sleep apnoea/hypopnoea syndrome.

We evaluated the efficiency of two different treatment procedures with continuous positive airway pressure (CPAP) on sleep, nocturnal breathing characteristics and daytime vigilance in 18 newly diagnosed patients with untreated sleep apnoea/hypopnoea syndrome (SAHS) randomly allocated to two different groups. In group I, the positive pressure (PP) level was set to suppress flow limitation (PFL)...

متن کامل

Comparison of three auto-adjusting positive pressure devices in patients with sleep apnoea.

Auto-adjustable continuous positive airway pressure (APAP) devices are an emerging treatment alternative to fixed-pressure continuous positive airway pressure (CPAP) therapy for obstructive sleep apnoea syndrome. They have been engineered to automatically adjust the pressure to the optimal level on a continuous basis. However, not all APAP technologies use the same algorithm. Three different AP...

متن کامل

Randomised placebo controlled trial of daytime function after continuous positive airway pressure (CPAP) therapy for the sleep apnoea/hypopnoea syndrome.

BACKGROUND Patients with the sleep apnoea/hypopnoea syndrome (SAHS) report improved sleepiness, cognitive function, and psychological well being after continuous positive airway pressure (CPAP) therapy, and it is for these daytime features that CPAP is usually given. However, few randomised or controlled studies exist on the effects of CPAP on daytime function. METHODS A prospective, randomis...

متن کامل

Alternatives for OSAHS treatment: selection of patients for upper airway surgery and oral appliances

Although continuous positive airway pressure (CPAP) is considered to represent the standard treatment for patients with moderate-to-severe obstructive sleep apnoea/hypopnoea syndrome (OSAHS), poor treatment compliance and/or refusal is an issue in ,20–30% of these

متن کامل

Compliance with CPAP therapy in patients with the sleep apnoea/hypopnoea syndrome.

BACKGROUND Continuous positive airway pressure (CPAP) therapy is the treatment of choice for the sleep apnoea/hypopnoea syndrome. Compliance with this relatively obtrusive therapy has not been well studied. METHODS Usage of CPAP was investigated in 54 patients with sleep apnoea/hypopnoea syndrome (median 36 (range 7-129) apnoeas + hypopnoeas/hour slept) over the first 1-3 months after startin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Thorax

دوره 51 2  شماره 

صفحات  -

تاریخ انتشار 1996