Efficacy and adverse effects of transpulmonary contrast echocardiography using sonicated albumin.
نویسندگان
چکیده
We studied the feasibility and adverse effects of transpulmonary contrast echocardiography using sonicated albumin in 6 dogs. Left heart contrast was observed by two-dimensional echocardiography, monitoring left ventricular pressure, its first derivative (dP/dt) and arterial oxygen saturation. The left heart was adequately opacified in 48 of 55 injections of various intravenous doses of sonicated albumin. Left ventricular myocardial opacification was faintly observed in only 1 injection. After injections of a large dose (0.5 ml/kg), left ventricular systolic pressure decreased, maximal positive dP/dt decreased and negative dP/dt increased, slightly. Hemodynamic parameters showed no significant changes with the other doses. Arterial oxygen saturation tended to decrease after injection, which was most remarkable with a large dose injection. In conclusion, although a large dose of intravenous sonicated albumin may opacify not only the left heart cavity but the ventricular myocardium, it deteriorates hemodynamic parameters and oxygen exchange in the lung.
منابع مشابه
[Contrast echocardiography. Does it have a future?].
In the past thirty years echocardiography has revolutionized cardiologic investigation. The non-invasive access to anatomy, physiology, and heart diseases has become increasingly broader. Since the introduction of the M-mode technique and, progressively, of twodimensional echocardiography, Doppler, color flow mapping, transesophageal echocardiogram, and use of physical or pharmacologic stress, ...
متن کاملContrast echocardiography for evaluation of left ventricular flow dynamics using densitometric analysis.
BACKGROUND Few data exist regarding intraventricular flow patterns in the presence of left ventricular dysfunction. Therefore, we examined the relation between intracavitary left ventricular flow dynamics and the presence of ventricular contractile abnormalities using videodensitometric analysis of transpulmonary contrast echocardiography. METHODS AND RESULTS Two-dimensional echocardiography ...
متن کاملSonicated echocardiographic contrast agents: reproducibility studies.
This article describes the production, analysis, and reproducibility of forming microbubbles for contrast ultrasound imaging. The sonication method used to generate microbubbles was tested by four independent observers, and a subsequent laser particle counter analysis of microbubble size and concentration determined the reproducibility of the method. The results indicated that the mean bubble s...
متن کاملThe behavior of sonicated albumin microbubbles within the microcirculation: a basis for their use during myocardial contrast echocardiography.
The purpose of this study was to determine whether the behavior of sonicated albumin microbubbles accurately mimics red blood cell flow in the microcirculation and is thus consistent with their use as in vivo tracers of red blood cell flow during myocardial contrast echocardiography. Accordingly, microbubbles prepared from fluorescein-conjugated albumin and fluorescently labeled red blood cells...
متن کاملEfficacy of Silybum Marianum Seeds in Ameliorating the Toxic Effects of Aflatoxin B1 in Broilers
Background: This study aims to evaluate the efficacy of silybum marianum seeds (SMSs) on blood biochemical profile of broiler chickens contaminated with Aflatoxin B1 (AFB1). Methods: Combinations of three levels of AFB1 (0, 250 and 500 ppb) with three levels of SMSs (0, 0.5, and 1.0 %) were incorporated into the basal diet (corn and soybean meal). The effect of nine experimental treatments was...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Internal medicine
دوره 33 4 شماره
صفحات -
تاریخ انتشار 1994