Repeatability of Non–Contrast-Enhanced Lower-Extremity Angiography Using the Flow-Spoiled Fresh Blood Imaging

نویسندگان

  • Yuyang Zhang
  • Zhen Xing
  • Dejun She
  • Nan Huang
  • Dairong Cao
چکیده

PURPOSE The aim of this study was to prospectively evaluate the repeatability of non-contrast-enhanced lower-extremity magnetic resonance angiography using the flow-spoiled fresh blood imaging (FS-FBI). METHODS Forty-three healthy volunteers and 15 patients with lower-extremity arterial stenosis were recruited in this study and were examined by FS-FBI. Digital subtraction angiography was performed within a week after the FS-FBI in the patient group. Repeatability was assessed by the following parameters: grading of image quality, diameter and area of major arteries, and grading of stenosis of lower-extremity arteries. Two experienced radiologists blinded for patient data independently evaluated the FS-FBI and digital subtraction angiography images. Intraclass correlation coefficients (ICCs), sensitivity, and specificity were used for statistical analysis. RESULTS The grading of image quality of most data was satisfactory. The ICCs for the first and second measures were 0.792 and 0.884 in the femoral segment and 0.803 and 0.796 in the tibiofibular segment for healthy volunteer group, 0.873 and 1.000 in the femoral segment, and 0.737 and 0.737 in the tibiofibular segment for the patient group. Intraobserver and interobserver agreements on diameter and area of arteries were excellent, with ICCs mostly greater than 0.75 in the volunteer group. For stenosis grading analysis, intraobserver ICCs range from 0.784 to 0.862 and from 0.778 to 0.854, respectively. Flow-spoiled fresh blood imaging yielded a mean sensitivity and specificity to detect arterial stenosis or occlusion of 90% and 80% for femoral segment and 86.7% and 93.3% for tibiofibular segment at least. CONCLUSIONS Lower-extremity angiography with FS-FBI is a reliable and reproducible screening tool for lower-extremity atherosclerotic disease, especially for patients with impaired renal function.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Noncontrast-enhanced peripheral MRA: technical optimization of flow-spoiled fresh blood imaging for screening peripheral arterial diseases.

Flow-spoiled fresh blood imaging, a noncontrast peripheral MR angiography technique, allows the depiction of the entire tree of peripheral arteries by utilizing the signal difference between systolic- and diastolic-triggered data. The image quality of the technique relies on selecting the right triggering delay times and flow-dependent read-out spoiler gradient pulses. ECG triggering delays wer...

متن کامل

Non-Contrast MRA

Introduction In MR angiography (MRA), techniques are mainly divided into contrast-enhanced MRA and non-contrast MRA. Various non-contrast MRA techniques are clinically useful and widely used in routine examinations, such as 3D TOF [1] in intracranial region, phase shift [2] for flow quantification, arterial spin labeling [3,4] in pulmonary vessels [5,6], and balanced SSFP [7] in bright blood ca...

متن کامل

A comparative analysis of noncontrast flow-spoiled versus contrast-enhanced magnetic resonance angiography for evaluation of peripheral arterial disease.

PURPOSE This feasibility study aimed to obtain initial data to assess the performance of a novel noncontrast spoiled magnetic resonance (MR) angiography technique (fresh-blood imaging [FBI]) compared to gadolinium-enhanced MR (Gd-MR) angiography for evaluation of the aorto-iliac and lower extremity arteries. MATERIALS AND METHODS Thirteen patients with suspected lower extremity arterial disea...

متن کامل

Quantification of blood-brain-barrier permeability dysregulation and inflammatory activity in MS lesions by dynamic-contrast enhanced MR imaging

Objective: Measurement of blood-brain permeability dysfunction in active and chronic MS lesions with T1-weighted dynamic contrast-enhanced MRI to show variation in inflammatory activity Background: blood-brain-barrier perfusion characterization impaired in MS as some studies have shown recently buta comparison between perfusion parameters in contrast-enhanced and non-enhanced lesions not have ...

متن کامل

طراحی پروتکل MR انژیوگرافی اندام تحتانی با استفاده از دستگاه 1.5MRI تسلا

Background and purpose: Ôn time diagnosis and treatment of lower limb diseases are of crucial importance to the patients. Çonventional angiography is the standard procedure of diagnosis, which is followed by different problems such as, X-ray hazards, sensitivity to contrast drugs and complications of opening vessel. Doppler ultrasonography has low differentiation power. MR angiography is a s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 42  شماره 

صفحات  -

تاریخ انتشار 2018