Interobserver agreement of contrast-enhanced harmonic endoscopic ultrasonography in the evaluation of solid pancreatic lesions

نویسندگان

  • João-Bruno Soares
  • Julio Iglesias-Garcia
  • Bruno Gonçalves
  • Björn Lindkvist
  • Jose Lariño-Noia
  • Pedro Bastos
  • Ana Célia Caetano
  • Aníbal Ferreira
  • Pedro Pimentel-Nunes
  • Luís Lopes
  • Pedro Moutinho
  • J. Enrique Dominguez-Muñoz
چکیده

BACKGROUND AND STUDY AIMS Previous reports assessing the reproducibility of contrast-enhanced harmonic endoscopic ultrasonography (CH-EUS) in the evaluation of solid pancreatic lesions (SPLs) involved mainly experienced endosonographers. We aimed to assess the interobserver agreement (IOA) of CH-EUS in the evaluation of SPLs by endoscopists with different levels of experience in EUS and CH-EUS. PARTICIPANTS AND METHODS A cross-sectional observational multicenter study was designed and included 11 endoscopists who were divided into four groups according to their experience in EUS and CH-EUS: group A (long experience in EUS and CH-EUS); group B (short experience in EUS and CH-EUS); group C (long experience in EUS and no experience in CH-EUS); and group D (no experience in EUS or CH-EUS). The observers independently classified the patterns of 60 CH-EUS video sequences of 60 SPLs after a 20-minute training session. For each group, we calculated the IOA (kappa statistic, κ) of CH-EUS and the accuracy of CH-EUS for the diagnosis of pancreatic adenocarcinoma by comparing the pattern of CH-EUS indicative of pancreatic adenocarcinoma (hypo-enhanced contrast pattern) with the final diagnosis. RESULTS The overall IOA for CH-EUS was fair (κ = 0.32; 95 %CI 0.22 - 0.41). Group A (κ = 0.63; 95 %CI 0.45 - 0.85) had the highest IOA, followed by group C (κ = 0.54; 95 %CI 0.39 - 0.71), group B (κ = 0.38; 95 %CI 0.22 - 0.55), and group D (κ = 0.21; 95 %CI 0.07 - 0.36). The IOA of groups A and C was significantly higher than that of group D. No significant difference was seen between groups A, B, and C or between groups B and D in terms of IOA. Group A (area under the curve under summary receiver operating characteristic [AUROC] = 0.67; 95 %CI 0.58 - 0.75) had the highest accuracy for the diagnosis of pancreatic adenocarcinoma, followed by group C (AUROC = 0.58; 95 %CI 0.50 - 0.65), group B (AUROC = 0.55; 95 %CI 0.48 - 0.63), and group D (AUROC = 0.51; 95 %CI 0.43 - 0.58). The diagnostic accuracy of group A was not significantly different from that of group C, but it was significantly higher than that of groups B and D. No significant difference was seen between groups B, C, and D in terms of diagnostic accuracy. CONCLUSIONS CH-EUS is reproducible in the evaluation of SPLs, even between endoscopists with no or limited experience in EUS and/or CH-EUS. Long experience in EUS is a major contributor to the IOA and diagnostic accuracy of CH-EUS.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Contrast-Enhanced Harmonic Endoscopic Ultrasound-Guided Fine-Needle Aspiration in the Diagnosis of Solid Pancreatic Lesions: A Retrospective Study

BACKGROUND The negative predictive value of endoscopic ultrasonography-guided fine needle aspiration for the diagnosis of solid pancreatic lesions remains low, and the biopsy specimens are sometimes inadequate for appropriate pathological diagnosis. AIMS To evaluate the usefulness of a novel method of contrast-enhanced harmonic endoscopic ultrasonography-guided fine-needle aspiration for the ...

متن کامل

Contrast-Enhanced Harmonic Endoscopic Ultrasonography in Pancreatic Diseases

Endoscopic ultrasonography (EUS) is the most sensitive imaging method for diagnosis of pancreatic tumors. However, it still has limits in the differentiation between pancreatic cancers and inflammatory tumor-like masses. A novel technology, contrast-enhanced harmonic EUS (CH-EUS), has been developed recently. It can visualize both parenchymal perfusion and microvasculature in pancreas without D...

متن کامل

Clinical Role of Contrast-Enhanced Harmonic Endoscopic Ultrasound in Differentiating Solid Lesions of the Pancreas: A Single-Center Experience in Korea

BACKGROUND/AIMS The differential diagnosis of pancreatic solid lesions remains challenging. The aim of this study was to investigate the accuracy of contrast-enhanced harmonic endoscopic ultrasound (CEH-EUS) in differentiating pancreatic cancer from benign lesions. METHODS We prospectively evaluated 37 patients with pancreatic solid lesions. After intravenous injection of a contrast agent (So...

متن کامل

Contrast-enhanced Harmonic Endoscopic Ultrasound in Differentiating Solid Lesions of Pancreas

Background/Aims: The differential diagnosis of pancreatic solid lesions still remains challenging. Recently, contrast-enhanced harmonic endoscopic ultrasound (CE-EUS) has been developed. The aim of this study is to investigate the accuracy of CEEUS in differentiating pancreatic cancer from benign pancreatic lesions by visualizing pancreatic microvasculature. Method: We prospectively evaluated 1...

متن کامل

New endoscopic ultrasonography techniques for pancreaticobiliary diseases

Endoscopic ultrasonography (EUS) is widely used to evaluate pancreaticobiliary diseases, especially pancreatic masses. EUS has a good ability to detect pancreatic masses, but it is not sufficient for the differential diagnosis of various types of lesions. In order to address the limitations of EUS, new techniques have been developed to improve the characterization of the lesions detected by EUS...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2015