Temperature changes during ultrasonic irrigation with different inserts and modes of activation.

نویسندگان

  • Marco Zeltner
  • Ove A Peters
  • Frank Paqué
چکیده

This study evaluated temperature changes during passive ultrasonic irrigation. Root canals of three extracted maxillary canines were enlarged to size #45. Thermocouples were mounted 3, 6, and 9 mm from the apical foramen. Teeth were placed in a water bath at 37 degrees C. Distilled water (20 degrees C) was continuously delivered through an ultrasonic unit (group 1) or deposited into the root canal before ultrasonic activation (group 2); for activation, noncutting nickel-titanium (NiTi) inserts or stainless steel K-files #15, #25, and #35 were used. Before and during ultrasonic activation, temperatures were continuously measured for 210 seconds. Statistical analysis was performed using analysis of variance and Scheffé post hoc tests. Temperatures initially decreased by up to 7.4 degrees C; these drops were significantly smaller in group 1 than in group 2 (p < 0.001) in the middle and apical root canal third. The decreases were followed by temperature rises for all inserts in group 2. However, in group 1, temperatures just reached baseline values in middle and apical thirds; in the coronal root canal third, lower temperatures were measured. In group 2, mean temperature rises were 7.7 degrees , 7.5 degrees , and 4.2 degrees C in coronal, middle, and apical root canal thirds. Here, K-file type inserts size #35 generated highest and inserts size #15 the lowest temperatures rises; NiTi inserts were more effective than size #15 K-files and less effective than #35 K-files. Continuous flow negated the potential of ultrasonic activation to heat irrigation solutions. Noncutting NiTi instruments and large K-files were more effective than small K-files in warming deposited irrigants.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Investigation of Brightness Changes in Ultrasound Images due to Temperature Variations in Liver Tissue during Radiofrequency Ablation

Introduction: one of the minimally invasive methods of treatmenting liver malignancies is Radiofrequency Ablation (RFA) which can be applied to primary or secondary tumors. Nevertheless, the disease recurrence is probable after RFA application partially due to the inadequate capability of temperature monitoring of the target tissue and visualizing the thermal damage. The goal of this work was t...

متن کامل

بررسی ضخامت اولتراسونیک عضلات دیوارۀ طرفی شکم حین انقباض عضلات کف لگن در زنان مبتلا به بی‌اختیاری استرسی ادرار با کمردرد مزمن و بدون کمردرد مزمن

Objective: Urinary Incontinence (UI) as a common lower urinary tract dysfunction , results from Pelvic Floor Muscle's (PFM) underactivity.Because of co-activation of PFM and the Lateral Abdominal Wall Muscles (LAWM), this study was aimed to investigate the changes in the ultrasonic thickness of the LAWM in response to PFM contraction in stress urinary incontinent (SUI)women with and without Chr...

متن کامل

Impact of Ultrasonic Activation on the Effectiveness of Sodium Hypochlorite: A Review

Using ultrasonic devices in endodontics can enhance the antibacterial and tissue dissolving ability of different root canal irrigants such as sodium hypochlorite (NaOCl) which is the most common irrigant with excellent antibacterial and tissue dissolving abilities. However, due to its high surface tension, its penetration into the irregularities of the root canal system is a challenge. The purp...

متن کامل

Ultrasonic guided waves reflection from simple dent in pipe for defect rate estimation and parameters determination of axisymmetric wave generation source

In this paper, the reflection of ultrasonic guided waves from simple dent in pipes has been investigated using finite element method and the relationship between reflection coefficient of these waves and deformation rate has been determined. Also, the effect of the parameters of wave generation source on the generated wave field has been investigated using normal modes expansion method. At firs...

متن کامل

Effect of composite shade, curing time and mode on temperature rise of silorane and methacrylate- based composite resins

Introduction: The present study was performed to evaluate the effects of light-curing modes and shades of methacrylate and silorane-based composite resins on temperature rise during polymerization of composite resins. Materials &Methods: In this in vitro study, ninety composite samples with two types of composite resin - methacrylate-based and a low-shrinkage silorane-based were prepared, in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of endodontics

دوره 35 4  شماره 

صفحات  -

تاریخ انتشار 2009