Lymphoscintigraphy is more effective using higher specific activity (99m)Tc-antimony trisulfide colloid in the rat.
نویسنده
چکیده
Technetium-99m-antimony trisulfide colloid ((99m)Tc-ATC) was investigated with varying specific activity in the rat lymphatic system, as well as its binding to rat blood cells in vitro. Low, moderate and high doses of (99m)Tc-ATC were subdermally injected into tails of rats (n=3) and 30min later whole body lymphoscintigraphic images were acquired. (99m)Tc-ATC was incubated for 30min at 37°C with whole blood (n=4) as for control, at 4°C as for hypothermia, as opsonized at 37°C and lipopolysaccharide (LPS) at 37°C. Cell types were separated by gradient centrifugation to assay for cell bound-radioactivity. These experiments were repeated using mixed leukocytes that were erythrocytes-free. Images showed direct drainage of (99m)Tc-ATC from the tail to the popliteal nodes, sacral node and beyond, along the para-aortic chain, and to a left inguinal lymph node that drained into the axillia. The higher specific activity dose resulted in more visible lymph nodes after 30min. (99m)Tc-ATC was predominantly not cell-bound. In rat whole blood (99m)Tc-ATC-neutrophils were only present to the extent of 3% for the control, 3% for the hypothermia test, 4% for the opsonized and 7% for the LPS test. In the erythrocytes-free samples, (99m)Tc-ATC-leukocytes were present to the extent of 5% (control), 4% (hypothermia), 6% (opsonized) and 11% (LPS). In conclusion, a higher specific activity radiocolloid may identify the sentinel lymph node sooner during lymphoscintigraphy, and there may be an advantage in detecting more counts with the γ-probe. Retention of (99m)Tc-ATC in lymph nodes in vivo is likely because of binding on macrophage surfaces, rather than from internalization by phagocytosis within a time frame of 30min after injection.
منابع مشابه
Sentinel node detection failure due to defective labeling and large particle size of Tc-99m antimony sulfide colloid
Introduction: Many radiotracers have been used for sentinel node mapping with acceptable results. The main difference between these radiotracers is the particle size. In the current study, we reported defective labeling of Tc-99m antimony sulfide colloid which resulted in large particle size. Methods: Tc-99m-Antimony sulfide colloid was used for axillary sentinel n...
متن کاملBody outlining using Tc-99m filled flood source for lymphoscintigraphy imaging
Introduction: In the current study, we evaluated the feasibility of body outlining using Tc-99m filled flood source for lymphoscintigraphy imaging. Methods: 80 patients were included in the study. Sentinel node mapping was done using Tc-99m Antimony sulfide colloid. For outlining the body a Tc-99m filled flood source was used which was placed behind or lateral to t...
متن کاملParticle size analysis of (99m)Tc-labeled and unlabeled antimony trisulfide and rhenium sulfide colloids intended for lymphoscintigraphic application.
UNLABELLED Colloidal particle size is an important characteristic to consider when choosing a radiopharmaceutical for mapping sentinel nodes in lymphoscintigraphy. METHODS Photon correlation spectroscopy (PCS) and transmission electron microscopy (TEM) were used to determine the particle size of antimony trisulfide and rhenium sulfide colloids, and membrane filtration (MF) was used to determi...
متن کاملProduction of 99mTc-Antimony Sulfide Colloid for lymphoscintigraphy [Persian]
Introduction: The lymphatic system provides one of the main paths for the spread (Metastasis) of cancer from one part of body to another. Hodgkin’s diseases, lymphocytic leukemia, various metastatic disease and many lymph node disorders can be assessed by lymphoscintigraphy. Radionuclide lymphoscintigraphy has been used for many years to define lymphatic drainage of melanoma. The most com...
متن کاملSentinel lymph node biopsy in melanoma patients: An experience with Tc-99m antimony sulfide colloid
Introduction: Sentinel lymph node biopsy is the standard procedure for lymph node staging in intermediate thickness melanoma. In Iran, this procedure has not been addressed sufficiently. In this study, we report our experience in this area. Methods: Ten consecutive patients with intermediate thickness melanoma where included in our study. 1.5 mCi of Tc-99m antimony...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Hellenic journal of nuclear medicine
دوره 17 1 شماره
صفحات -
تاریخ انتشار 2014