Evaluation of central venous catheters coated with a noble metal alloy-A randomized clinical pilot study of coating durability, performance and tolerability.

نویسندگان

  • Gunilla Björling
  • Dorota Johansson
  • Linda Bergström
  • Anton Strekalovsky
  • Javier Sanchez
  • Claes Frostell
  • Sigridur Kalman
چکیده

The use of Central Venous Catheters (CVCs) commonly results in complications. Coatings with silver or metal alloys can reduce the risk associated with the use of CVC. We have evaluated the durability of a noble metal coated CVC (the Bactiguard Infectious Protection, BIP CVC) and compared with an uncoated CVC for clinical tolerability (Adverse Events, AEs) and performance, in order to create a baseline for a large future study. Patients undergoing major surgery, randomised at a 2:1 ratio to BIP CVC (n = 22) or standard CVC (n = 12), were catheterized 9 - 12 days, respectively. Adverse events, microbial colonization and metal release were measured. FINDINGS There were no AEs in the BIP CVC-group, but 5 AEs occurred in 4 patients (1 patient had 2 AEs) in the standard CVC-group, p = 0.011 (whereof 3 were catheter related). The BIP CVC showed an initial release of coating metals in blood (gold, silver and palladium), which rapidly decreased and were far below Permitted Paily Exposure (PDE) for chronical use. The levels of silver concentration were far below those needed to develop microbial resistance. The performance was equal, and there was no difference concerning microbial colonization, for the two CVCs. CONCLUSION In this pilot study the BIP CVC had significantly lower AEs and showed a comparable performance to the standard CVC. The coating was durable throughout the study length (up to 16 days) and toxicological evaluation showed good safety margins. Larger studies are needed. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2017.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tolerability and performance of BIP endotracheal tubes with noble metal alloy coating – a randomized clinical evaluation study

BACKGROUND Hospital acquired infections worsen the outcome of patients treated in intensive care units and are costly. Coatings with silver or metal alloys may reduce or alter the formation of biofilm on invasive medical devices. An endotracheal tube (ETT) is used to connect the patient to a ventilator and coated tubes have been tested in relation to bacterial colonization and respiratory infec...

متن کامل

Improved ex vivo blood compatibility of central venous catheter with noble metal alloy coating

Central line associated bloodstream infections (CLABSIs) are a serious cause of morbidity and mortality induced by the use of central venous catheters (CVCs). Nobel metal alloy (NMA) coating is an advanced surface modification that prevents microbial adhesion and growth on catheters and thereby reduces the risk of infection. In vitro microbiological analyses have shown up to 90% reduction in mi...

متن کامل

A Comparison effect of collaborative-based training program and lecture method on nurses’ performance of central venous catheter care

Background and Objectives: Improving nurses’ adherance with nursing standard catheter care is needed to enhance the quality of central venous catheters care. This study aimed to compare the effect of collaborative teaching method and lecture method on nursesing care of Central venous catheters. Materials and Methods: This quasi- experimental pretest-post test design study was conducted...

متن کامل

Preparation and in-vitro Antibacterial Evaluation of Electroless Silver Coated Polymers

Long-term use of indwelling medical catheters has often been hindered by catheter-associated nosocomial infections. In this study the effectiveness of silver coating of polystyrene and polyethylene polymers was investigated. Polymer pieces of 2 cm2 each were coated with a thin layer of silver using electroless plating technique. Silver-coated polymers were challenged with cultures of four diffe...

متن کامل

Preparation and in-vitro Antibacterial Evaluation of Electroless Silver Coated Polymers

Long-term use of indwelling medical catheters has often been hindered by catheter-associated nosocomial infections. In this study the effectiveness of silver coating of polystyrene and polyethylene polymers was investigated. Polymer pieces of 2 cm2 each were coated with a thin layer of silver using electroless plating technique. Silver-coated polymers were challenged with cultures of four diffe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomedical materials research. Part B, Applied biomaterials

دوره   شماره 

صفحات  -

تاریخ انتشار 2017