'Progression towards the minimum': the importance of standardizing the priming volume during the indirect measurement of intra-abdominal pressures

نویسندگان

  • Chad G Ball
  • Andrew W Kirkpatrick
چکیده

The abdominal compartment syndrome is a state of serious organ dysfunction. The syndrome results from sustained intra-abdominal hypertension, which is indirectly identified by measuring intra-bladder pressures (IBPs) using various priming volumes. This technique is poorly standardized across published data. Malbrain and Deeren have identified the risk of falsely elevated IBPs with instillation priming volumes greater than 50 ml. This overestimation appears to increase with larger priming aliquots. As a result, erroneous IBP measurements may incorrectly label a patient with the abdominal compartment syndrome, and therefore subject them to the potential complications of surgical and/or medical decompression techniques. The utility and benefit of using continuous IBP monitoring is discussed. These data require confirmation in other patient subgroups with younger ages, altered body mass indices and varied diagnoses.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Intra-abdominal Pressure Measurement and Physical Exam for Diagnosis of Surgery Indication in Patients with Abdominal Compartment Syndrome due to Blunt Trauma

Background & Aims: Increase in abdominal pressure can lead to the so-called intra–abdominal compartment syndrome (ACS) that is often observed during the first 24 hours after sever abdominal trauma and surgery. Measurement of the intra abdominal pressure through the bladder as a non-invasive measurement can provide a quick and accurate assessment of abdominal pressure changes. This study was per...

متن کامل

Comparison of direct and indirect methods of intra-abdominal pressure measurement in normal horses.

OBJECTIVES To develop a direct method for measuring intra-abdominal pressures in the standing horse, identify a reference interval for direct intra-abdominal pressures, compare these pressures to indirect intra-abdominal pressures measured from the bladder, and determine the optimal bladder infusion volume for indirect pressure measurement. DESIGN Prospective, experimental study. SETTING A ...

متن کامل

CARBON DIOXIDE MINIMUM MISCIBILITY PRESSURE ESTIMATION (CASE STUDY)

Carbon dioxide flooding is considered to be one of the most effective enhanced oil recovery methods for the light oil reservoirs. Depending on the operating pressure, the process might be miscible or immiscible. Minimum miscibility pressure (MMP) is the most important parameter for assessing the applicability of any miscible gas flood for an oil reservoir. The miscibility condition is determine...

متن کامل

Evaluating intra-abdominal pressures in a porcine model of acute lung injury by using a wireless motility capsule

BACKGROUND Intra-vesical pressure measurement as the reference standard for assessing intra-abdominal pressures is mainly indirect and discontinuous. We therefore evaluated a motility capsule for continuous intra-abdominal pressure measurement in an animal model with a high probability for capillary leakage and intestinal edema. MATERIAL/METHODS Motility capsules were inserted into the stomac...

متن کامل

Assessing Predictive Power of the Abdominal Volume Index Compared to other Anthropometric Indices and Its Association with Risk Factors of Cardiovascular Diseases

Background and Objectives: Obesity is associated with cardiovascular risk factors and may increase the prevalence of these factors. This study aimed to assess predictive power of the abdominal volume index compared to other anthropometric indices and its association with the risk of cardiovascular  diseases.  Materials & Methods: This cross-sectional study hired 300 men and non-pregnant women....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Critical Care

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2006