QbD Based Method Development on an Agilent 1290 Infinity UHPLC System Combined with a Seamless Method Transfer to HPLC Using Intelligent System Emulation Technology

ثبت نشده
چکیده

In this Application Note, a method was developed on sub-2 μm particle columns and transferred to a conventional HPLC method using Quality by Design (QbD) principles. A seamless method transfer between the different chromatography systems was achieved using the Agilent Intelligent System Emulation Technology (ISET). Initial method development work on the Agilent Infinity 1290 system included automated chemistry screening of different sub-2 μm particle columns under different chromatographic conditions involving multiple combinations of eluents, flow rates, gradient slopes, and temperatures. Subsequent optimization of the best performing chemistry system was carried out using a Design of Experiments (DOE) approach to establish the ICH Design Space. The Agilent Method Translator was used for the transfer from sub-2 μm column material to conventional column material. An Agilent 1290 Infinity UHPLC system was used in combination with ISET to emulate an Agilent 1260 Infinity HPLC system. This enabled establishing a Design Space for the HPLC method. Reproducibility and resolution of the transferred method was then verified on an Agilent 1260 Infinity HPLC system. This successfully demonstrates that ISET in combination with Fusion QbD Method Development and Validation Software (S-Matrix) enables an efficient transfer of UHPLC methods to HPLC methods within the QbD approach.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fast screening of mobile and stationary phases with the Agilent 1290 Infinity LC and seamless method transfer to an Agilent 1200 Series LC using ISET

This Application Note describes how the Agilent 1290 Infinity LC System Method Development Solution was used to find optimum separation conditions for degradation products of a pharmaceutical preparation. Having evaluated the optimum combination, a transfer to conventional conditions was performed. Finally, the Agilent Intelligent System Emulation Technology (ISET) of the 1290 Infinity LC was u...

متن کامل

Analysis of fat-soluble vitamins from food matrix for nutrition labeling

This Application Note shows how to carry out qualitative and quantitative analysis of fat soluble vitamins from two different food matrixes. A robust reverse phase high performance liquid chromatographic (RP-HPLC) method for simultaneous determination of nine fat soluble vitamins was developed. Separation and quantification was achieved by an Agilent 1260 Infinity LC System using an Agilent Por...

متن کامل

High-Resolution Analysis of Intact Triglycerides by Reversed Phase HPLC Using the Agilent 1290 Infinity LC UHPLC System

The Agilent 1290 Infinity LC System with ultraviolet/visible (UV/VIS) Diode Array detection (DAD) is used to analyze triglycerides in soybean oil under non-aqueous reversed phase gradient conditions. The Agilent 1290 Infinity LC System was used for the chromatographic separation of the sample on 3.0 and 2.1 mm id C18 columns, of various lengths, with 1.8-μm packing materials prepared in 600 bar...

متن کامل

Analysis of water-soluble vitamins from multivitamin tablets for nutrition labeling

In this Application Note we describe an application solution to carry out qualitative and quantitative analysis of water soluble vitamins. We developed a single and robust reverse phase high performance liquid chromatographic (RP-HPLC) method for simultaneous determination of 10 different vitamins unlike a number of different traditional methods which quantify the components individually. Separ...

متن کامل

Analysis of TCM injections using the Agilent 1290 Infinity LC system

An ultra high performance liquid chromatography (UHPLC) method using an Agilent 1290 Infinity LC system with an Agilent 1290 Infinity Diode Array Detector (DAD) was developed for the separation of Shenmai injections. Good separation of complex systems was achieved by connecting two columns: an Agilent ZORBAX Eclipse Plus C18 column (2.1 mm × 100 mm, 1.8 μm) and an Agilent ZORBAX SB C18 (2.1mm ×...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015