Polyaxial versus uniaxial volar locking plate for distal radial fractures.
نویسندگان
چکیده
PURPOSE To compare the penetration of the distal screws in relation to the thickness of the distal metaphysis in the polyaxial versus uniaxial volar locking plates. METHODS Records of 78 patients aged 16 to 79 years who underwent open reduction and internal fixation for distal radial fractures (n=81) were reviewed. All fracture subtypes were included. 20 men and 22 women aged 18 to 79 (mean, 50) years were treated with the uniaxial locking plate, whereas 15 men and 21 women aged 16 to 79 (mean, 51) years were treated with the polyaxial locking plate. The choice of plate was determined by the operating surgeon based on familiarity and perceived advantages of the 2 plates. Penetration of the distal locking screws in relation to the volar-dorsal thickness of the distal radial metaphysis was measured, and the percentage of subchondral bone unsupported by the screws calculated. RESULTS The mean percentage of unsupported subchondral bone was significantly lower in the polyaxial than uniaxial volar locking plate group (12% vs. 23%, p<0.001). No patient had screw over-penetration. CONCLUSION The polyaxial volar locking plate system enabled deeper insertion of distal screws into the subchondral bone, and thus providing better buttress for the fracture fragments.
منابع مشابه
Polyaxial locking plate fixation in distal femur fractures: a biomechanical comparison.
OBJECTIVES Uniaxial, first-generation locking plates have become increasingly popular for fixation of supracondylar femur fractures. Polyaxial plates are currently available, which allow for variable-angle screw insertion; however, the biomechanical integrity of these new locking constructs is yet unproven. This study compares the mechanical stability of a conventional locking plate with that o...
متن کاملComparison of volar locking plate and external fixation with K wire augmentation in unstable distal radius fractures
Distal radius fractures are one of the most common injuries and this incidence is likely to increase as the aging population increases. The type of operation and implant is a matter of discussion and randomized trials and meta analyses have failed to recommend the preferred implant. Internal fixation with volar locking plate and external fixation with supplementation with K wire have been succe...
متن کاملInternal fixation of dorsally displaced fractures of the distal part of the radius. A biomechanical analysis of volar plate fracture stability.
BACKGROUND Volar plate fixation with use of either a locking plate or a neutralization plate has become increasingly popular among surgeons for the treatment of dorsally comminuted extra-articular distal radial fractures. The purpose of the present study was to compare the relative stability of five distal radial plates (four volar and one dorsal), all of which are commonly used for the treatme...
متن کاملVolar locking plate fixation versus Kirschner wire fixation in distal radius fractures: a meta-analysis
Objective: The superiority of volar locking plate fixation and K-wire fixation on treatment of distal radius fractures was controversial. Thus, we performed a meta-analysis to compare the efficacy of volar locking plate and K-wires for distal radius fracture. Methods: We searched Embase, Medline and PubMed for randomized controlled trials which compare the effects of volar locking plate and K-w...
متن کاملVolar locking-plate and Kirschner-wire fixation did not differ in terms of functional outcomes after dorsally displaced distal radial fracture.
Volar locking-plate and kirschner-wire fixation did not differ in terms of functional outcomes after dorsally displaced distal radial fracture.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of orthopaedic surgery
دوره 22 1 شماره
صفحات -
تاریخ انتشار 2014