A Calibration and Quality Assurance Program for Environmental Radon Measurements

نویسندگان

  • Isabel M. Fisenne
  • Andreas C. George
  • Helen W. Keller
چکیده

The ideal facility for assessing the quality of radon measurements at environmental levels consists of: (1) an instrument whose response to radon and its progeny is determined from measurements of a certified or standard 226Ra source, and (2) a calibration room with a known radon concentration. The linkage between these two elements and additional quality control requirements are discussed here for some Environmental Measurements Laboratory radon measurements programs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Calibration and optimization of a low cost diffusion chamber for passive separated measurements of radon and thoron in soil by Lexan PC SSNTD

Background: Separate radon and thoron measurements in soil are very important in assessment of internal exposure due to inhalation of such radioactive gases. Materials and Methods: In this study, a low cost, small size, passive diffusion chamber has been developed for simple measurement of Radon-222 and Radon-220(Thoron) gases separately in soil. The diffusion chamber consists of two films and ...

متن کامل

Indoor exposure assessment of radon in the elementary schools, Palestine

Background: Many public health agencies rank residential radon exposure as the second leading cause of lung cancer after cigarette smoking. It has been shown that the risk coefficient for lung cancer is higher for children than that for adults. Therefore, indoor radon measurements were carried out in the elementary schools of Tulkarem province, West Bank, Palestine. Materials and Methods: Two h...

متن کامل

Indoor radon measurements in residential dwellings in Qom, Iran

Background: Inhalation of radon and its short-lived decay products is one of the ‎most significant sources of exposure to natural radiation. Radon is the second cause ‎of lung cancer in the populations. The present study was carried out under the projects of ‎national radon, with the aim of determining the concentration of indoor in the city of Qom ‎located in the central se...

متن کامل

Calibration of Scintillation Cells for Radon-222 Measurements at the U.S. Environmental Protection Agency

Zinc sulfide coated scintillation cells are the primary method for measuring radon-222 at the U.S. Environmental Protection Agency (EPA), Office of Radiation Programs (ORP), Eastern Environmental Radiation Facility (EERF). These cells are used to measure concentrations of radon in exposure chambers that are used to calibrate or test other devices or instruments. Individual cells are calibrated ...

متن کامل

Radon Measurement Standards and Calibration

This issue of the Journal of Research of the National Institute of Standards and Technology resulted from a one-half day seminar devoted to descriptions of the current status of the metrology of radon in international laboratories specializing in that area. The seminar, held June 5, 1989, at the Physikalisch-Technische Bundesanstalt (PTB), Braunschweig, Federal Republic of Germany was co-sponso...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 95  شماره 

صفحات  -

تاریخ انتشار 1990