Use of a continuous glucose sensor in an extracorporeal life support circuit.
نویسندگان
چکیده
BACKGROUND Standard care for infants on extracorporeal life support (ECLS) relies on intermittent measurement of blood glucose (BG); however, this can lead to significant changes in BG that go unrecognized for several hours. The present study was designed to assess performance and clinical applicability of a subcutaneous glucose sensor technology modified for use as a blood-contacting sensor within the ECLS circuit. METHODS Twelve children, aged 3 years or less, requiring ECLS support were studied. Three continuous glucose sensors (Medtronic MiniMed) were inserted into hubs placed in line with the ECLS circuit. Blood glucose was assessed with a laboratory analyzer (BG(LAB); Bayer Rapidlab 860) approximately every 5 h (mean 4.9 ± 3.3 h) with more frequent samples obtained with a bedside monitor (HemoCue) as needed. Sensor current (I(SIG)) was transmitted to a laptop computer and retrospectively calibrated using BGLAB. Sensor performance was assessed by mean absolute relative difference (MARD), linear regression slope and intercept, and correlation, all with BGLAB as reference. RESULTS The BGLAB averaged 107.6 ± 36.4 mg/dl (mean ± standard deviation) ranging from 58 to 366 mg/dl. The MARD was 11.4%, with linear regression slope (0.86 ± 0.030) and intercept (9.0 ± 3.2 mg/dl) different from 1 and 0, respectively (p < .05), and correlation (r² = 0.76; p < .001). The system was not associated with any adverse events, and placement and removal into the hubs was easily accomplished. Instances in which more frequent BG values were obtained using a bedside HemoCue (BGHEMO) monitor showed the sensor to respond rapidly to changes. CONCLUSIONS We conclude that continuous sensors can be adapted for use in an ECLS circuit with accuracy similar to or better than that achieved with the subcutaneous site. Continuous glucose monitoring in this population can rapidly detect changes in BG that would not otherwise be observed. Further studies will be needed to assess the benefit of continuous glucose monitoring in this population.
منابع مشابه
Use of a multi-modality life support system.
The purpose of this study was to describe the design and utilization of a multi-modality life support system (MMLSS), which is used to provide extracorporeal support for cases such as left heart bypass (LHB), extracorporeal life support (ECLS), veno-venous bypass, and hypothermic resuscitation. The design of the MMLSS consisted of a mobile cart outfitted with a centrifugal pump, heater cooler, ...
متن کاملAdjunctive Therapies During Extracorporeal Membrane Oxygenation to Enhance Multiple Organ Support in Critically Ill Children
Since the advent of extracorporeal membrane oxygenation (ECMO) over 40 years ago, there has been increasing interest in the use of the extracorporeal circuit as a platform for providing multiple organ support. In this review, we will examine the evidence for the use of continuous renal replacement therapy, therapeutic plasma exchange, leukopheresis, adsorptive therapies, and extracorporeal live...
متن کاملThe use of continuous renal replacement therapy in series with extracorporeal membrane oxygenation.
A large percentage of patients on extracorporeal membrane oxygenation (ECMO) require continuous renal replacement therapy (CRRT) usually performed through a different venous access or by introducing a filter into the ECMO circuit. Here, we evaluated the efficacy and safety of including a CRRT machine in the circuit by connecting its inlet line after the centrifugal pump and its outlet line befo...
متن کاملIn-vitro quantification of gaseous microemboli in two extracorporeal life support circuits.
During the course of extracorporeal membrane oxygenation, patients are at constant risk of exposure to air emboli. Air emboli may enter the circuit during routine lab sampling, medication administration, air entrainment through the venous cannula, or via a circuit disruption. Circuit components have been designed and positioned to minimize the quantity of air that travels through the arterial l...
متن کاملHow to perform a haemodialysis using the arterial and venous lines of an extracorporeal life support.
Continuous renal replacement therapy is particularly suited in the setting of acute renal failure, occurring after cardiac surgery, in patients requiring extracorporeal life support (ECLS) or membrane oxygenation. In such patients, temporary catheters are not necessary since the circuit of haemodialysis or haemofiltration may be connected on the ECLS cannulae. We report how to modify a classica...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of diabetes science and technology
دوره 5 1 شماره
صفحات -
تاریخ انتشار 2011