Novel Computational Methods for Image Analysis and Quantification Using Position Sensitive Radiation Detectors

نویسنده

  • Alejandro Sánchez Crespo
چکیده

The major advantage of position sensitive radiation detector systems lies in their ability to non invasively map the regional distribution of the emitted radiation in real-time. Three of such detector systems were studied in this thesis, gamma-cameras, positron cameras and CMOS image sensors. A number of physical factors associated to these detectors degrade the qualitative and quantitative properties of the obtained images. These blurring factors could be divided into two groups. The first group consists of the general degrading factors inherent to the physical interaction processes of radiation with matter, such as scatter and attenuation processes which are common to all three detectors The second group consists of specific factors inherent to the particular radiation detection properties of the used detector which have to be separately studied for each detector system. Therefore, the aim of this thesis was devoted to the development of computational methods to enable quantitative molecular imaging in PET, SPET and in vivo patient dosimetry with CMOS image sensors. The first task was to develop a novel quantitative dual isotope method for simultaneous assessments of regional lung ventilation and perfusion using a SPET technique. This method included correction routines for photon scattering, non uniform attenuation at two different photon energies (140 and 392 keV) and organ outline. This quantitative method was validated both with phantom experiments and physiological studies on healthy subjects. The second task was to develop and clinically apply a quantitative method for tumour to background activity uptake measurements using planar mammo-scintigraphy, with partial volume compensation. The third stage was to produce several computational models to assess the spatial resolution limitations in PET from the positron range, the annihilation photon noncollineairy and the photon depth of interaction. Finally, a quantitative image processing method for a CMOS image sensor for applications in ion beam therapy dosimetry was developed. From the obtained phantom and physiological results it was concluded that the methodologies developed for the simultaneous measurement of the lung ventilation and perfusion and for the quantification of the tumour malignancy grade in breast carcinoma were both accurate. Further, the obtained models for the influence that the positron range in various human tissues, and the photon emission non-collinearity and depth of interaction have on PET image spatial resolution, could be used both to optimise future PET camera designs and spatial resolution recovery algorithms. Finally, it was shown that the proton fluence rate in a proton therapy beam could be monitored and visualised by using a simple and inexpensive CMOS image sensor.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantification of Partial Volume Effects in Salivary Glands SPECT Images after Radiation Therapy of Head and Neck Tumors

Introduction: Radical radiation therapy of head and neck cancers may injure the salivary glands and reduce their function. Single-photon emission computed tomography (SPECT) images maybe used to evaluate function post-therapy. However, accurate quantification is hindered by the partial volume effects (PVEs). The present study involved the introduction of a PVEs quantif...

متن کامل

Calibration curves for on-line leakage detection using radiotracer injection method

One of the most important requirements for industrial pipelines is the leakage detection. In this paper, detection of leak and determination of its amount using radioactive tracer injection method has been simulated by Monte Carlo MCNP code. The detector array included two NaI (Tl) detectors which were located before and after the considered position, measure emitted gamma from radioactive trac...

متن کامل

A Method for Reduction of Parallax Broadening in Gas-Based Position Sensitive Detectors

A description is given of the principle and experimental verification of a new method which significantly reduces broadening of the position response, due to parallax, for radiation incident on a detector at finite angles of incidence. The technique, which can be implemented in gas-based position-sensitive detectors with planar geometry, substantially improves position resolution for scattering...

متن کامل

 A novel approach to automatic position calibration for pixelated crystals in gamma imaging

Introduction: The position estimation in gamma detection system will have constant misplacements which can be corrected in the calibration procedure. In the pixelated crystal uniformly irradiation of detector will produce irregular shape due to position estimation errors. This image is called flood field image and is used to calibrate the position estimation. In this work we pr...

متن کامل

Source Detection and Image Reconstruction with Position–Sensitive Gamma–Ray Detectors

Source Detection and Image Reconstruction with Position–Sensitive Gamma–RayDetectors byDaniel J. Lingenfelter Chair: Professor Jeffrey A. Fessler Gamma–ray detectors have important applications in security, medicine, and nu-clear non–proliferation. This thesis investigates the use of regularization to improveimage reconstruction and efficient methods for predicting source detect...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005