Incorrect use of pressurised metered dose inhaler by asthmatic patients.

نویسندگان

  • B M Zainudin
  • A W Sufarlan
چکیده

The use of pressurised metered dose inhalers was assessed among 93 asthmatic patients attending the respiratory out patient clinic between January to October 1989. They were regular users of the inhalers prior to the assessment. 62.4% of the patients were found to use the inhalers incorrectly. Forty three percent made more than one error. The commonest error observed was the failure to actuate and inhale the aerosol together in 41.9%. There was no difference in the occurrence of incorrect performance between different sexes, age groups, duration of inhaler used and previous supervision or no supervision by the doctors.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improvement of drug delivery with a breath actuated pressurised aerosol for patients with poor inhaler technique.

BACKGROUND The metered dose inhaler is difficult to use correctly, synchronising actuation with inhalation being the most important problem. A breath actuated pressurised inhaler, designed to help patients with poor inhaler technique, was compared with a conventional metered dose inhaler in terms of aerosol deposition and bronchodilator response. METHODS Radioaerosol deposition and bronchodilat...

متن کامل

Systematic review of clinical effectiveness of pressurised metered dose inhalers versus other hand held inhaler devices for delivering corticosteroids in asthma.

OBJECTIVE To determine the clinical effectiveness of pressurised metered dose inhalers (with or without spacer) compared with other hand held inhaler devices for the delivery of corticosteroids in stable asthma. DESIGN Systematic review of randomised controlled trials. DATA SOURCES Cochrane Airways Group trials database (Medline, Embase, Cochrane controlled clinical trials register, and han...

متن کامل

Effect of terbutaline on mucociliary clearance in asthmatic and healthy subjects after inhalation from a pressurised inhaler and a dry powder inhaler.

BACKGROUND beta Agonists have been shown to increase mucociliary clearance in some studies but not all. Whether the formulation of beta agonists affects mucociliary clearance is not known but may be important as the use of dry powder inhalers increases. METHODS The effect of different methods of administration of inhaled terbutaline on mucociliary clearance and forced expiratory volume in one...

متن کامل

Comparison of bronchodilator responses and deposition patterns of salbutamol inhaled from a pressurised metered dose inhaler, as a dry powder, and as a nebulised solution.

The lung dose and deposition patterns of drug delivered by dry powder inhaler are not known. The effects of inhaling 400 micrograms salbutamol delivered by dry powder inhaler (two 200 micrograms salbutamol Rotacaps), by pressurised metered dose inhaler, and by Acorn nebuliser were studied in nine subjects with chronic stable asthma. Technetium-99m labelled Teflon particles were mixed with micro...

متن کامل

Comparison of terbutaline and placebo from a pressurised metered dose inhaler and a dry powder inhaler in a subgroup of patients with asthma.

BACKGROUND Reversibility after administration of an inhaled bronchodilator is not always demonstrable in patients with asthma. Bronchodilator aerosol-induced bronchoconstriction has also been reported to occur in some patients. METHODS Fifteen selected patients showing < 10% improvement in forced expiratory volume in one second (FEV1) when tested with four doses of salbutamol (0.1 mg/dose) or...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Medical journal of Malaysia

دوره 45 3  شماره 

صفحات  -

تاریخ انتشار 1990