Accuracy Verification of Simplified Error Correction Method in Digital Electricity Meters
نویسندگان
چکیده
There are practically four main error sources in digital sampling electricity meters: errors of analogue input circuits, errors of the sampling process, errors of analogue-to-digital (A/D) conversion and errors of digital calculations. Brief description of correction of these errors is given. Very often it is not possible to make correction of every sample. Then, only the final calculated values are corrected and, thus, additional errors are introduced. MATLAB environment was used to find out the errors of such simplified calculations of the active power and the rms value of the voltage in case of harmonic and nonharmonic voltages and currents.
منابع مشابه
Optimal fast digital error correction method of pipelined analog to digital converter with DLMS algorithm
In this paper, convergence rate of digital error correction algorithm in correction of capacitor mismatch error and finite and nonlinear gain of Op-Amp has increased significantly by the use of DLMS, an evolutionary search algorithm. To this end, a 16-bit pipelined analog to digital converter was modeled. The obtained digital model is a FIR filter with 16 adjustable weights. To adjust weights o...
متن کاملVerification of the Accuracy of the Delivered Dose in Pelvic and Breast Cancer Radiotherapy by in-vivo Semi-Conductor Dosimetry
Introduction: Delivering maximum dose to tumor and minimum dose to normal tissues is the most important goal in radiotherapy. According to ICRU, the maximum acceptable uncertainty in the delivered dose compared to the prescribed dose should be lower than 5%, and this is because of the relationship between absorbed dose, tumor control and normal tissue damage. Absorbed dose accuracy is investiga...
متن کاملEffects of Digital Elevation Model (DEM) Spatial Resolution on the Recognition of Physiography Characteristics of the Basin )A Case Study of Shahrchai Watershed)
In recent years with developing geographic information systems tools, modeling and simulating methods has been developed quickly. Availability of accurate base maps is the basis of the cell sizes determination and preparing digital hydrologic models. Removing errors and minimizing of uncertainty factors in the digital models play the main role in improving the accuracy of the maps. The main pur...
متن کاملThe Impact of Immediate Grammatical Error Correction on Senior English Majors’ Accuracy at Hebron University
This study aimed at investigating the effects of grammatical error correction on EFL learners’ accuracy. Twenty-two male and female senior students were chosen randomly to respond to a questionnaire investigating their beliefs about immediate grammatical error correction. Actually, the study was conducted in order to answer this question: what is the effect of grammatical error feedback on stu...
متن کاملThe Impact of Immediate Grammatical Error Correction on Senior English Majors’ Accuracy at Hebron University
This study aimed at investigating the effects of grammatical error correction on EFL learners’ accuracy. Twenty-two male and female senior students were chosen randomly to respond to a questionnaire investigating their beliefs about immediate grammatical error correction. Actually, the study was conducted in order to answer this question: what is the effect of grammatical error feedback on stu...
متن کامل