Quality control of measurements of pH, carbon dioxide tension, and total carbon dioxide in plasma.

نویسندگان

  • D J Savory
  • J D Pryce
چکیده

We have measured total carbon dioxide in plasma with a new carbon dioxide analyzer, and compared the results with total carbon dioxide data derived from measurements of carbon dioxide tension and pH. The results agree sufficiently well to demonstrate that the new instrument provides a simple, efficient procedure for monitoring the precision and accuracy of pH, carbon dioxide tension, or total carbon dioxide in plasma.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Long-term reproducibility of a new pH/blood-gas quality-control system compared to two other procedures.

The long-term precision and stability of a new quality-control system for blood pH and gas measurements are compared to that of tonometered bicarbonate solutions and serum-based preparations. The new system, consisting of gas-equilibrated bicarbonate solutions in glass ampuls, is shown to be as stable as the serum-based preparation, and as reproducible as either of the other methods. The new sy...

متن کامل

End-tidal Carbon Dioxide Measurements in Unintentional Non-Fire-Related Carbon Monoxide Poisoning

Background: Poisoning with carbon monoxide occurs occasionally worldwide, and the gold diagnostic standard is to measure carboxyhemoglobin level in the blood. This study investigated the correlation between carboxyhemoglobin and the end-tidal carbon dioxide levels in 50 patients with carbon monoxide poisoning. Methods: We recruited 50 volunteer patients who had been admitted to the Emergency S...

متن کامل

Adaptation of the Cyanobacterium fischerella sp. ISC 107 to the combined effects of pH and carbon dioxide concentration. Mahboobeh Rajabnasab1, Ramezan Ali Khavari-nejad1*, Shademan Shokravi2 and Taher Nejadsattari1

The aim of this study was to investigate the adaptation of the cyanobacterium Fischerella sp. ISC 107to combined effects of carbon dioxide concentration, acidic and alkalinity. Axenic strain was incubated in BG0-11 medium. Carbon dioxide treatments were limited and relatively non-limited. Acidic (pH 5), neutral (pH7), and alkaline (pH 9) conditions were employed in each treatment. Survival, gro...

متن کامل

An Experimental Investigation of Reactive Absorption of Carbon Dioxide into an Aqueous NH3/H2O/NaOH Solution

In this research, the reactive absorption of carbon dioxide in an aqueous solution of NH3, H2O, and NaOH has experimentally been investigated. The experiments were carried out in an absorption pilot plant in different operational conditions. The composition and temperature of both gas and liquid phases were obtained during the column height. The concentration of molecular ...

متن کامل

Experimental Investigation and Modeling of Carbon Dioxide Adsorption from Model Flue gas

In this work, the adsorption of carbon dioxide from model flue gas on different adsorbents has been investigated. Using simplified modeling, parameters such as the total mass transfer coefficient and the effective diffusivity have been determined. Experiments were carried out in two sections: firstly, adsorption of pure carbon dioxide on different adsorbents was measured at pressures ranging fr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 24 9  شماره 

صفحات  -

تاریخ انتشار 1978