A novel knee prosthesis model of implant-related osteo- myelitis in rats

نویسندگان

  • Niels H Søe
  • Nina Vendel Jensen
  • Birgit Meinecke Nürnberg
  • Asger Lundorff Jensen
  • Janne Koch
  • Steen Seier Poulsen
  • Gerald Pier
  • Helle Krogh Johansen
چکیده

BACKGROUND AND PURPOSE There have been numerous reports of animal models of osteomyelitis. Very few of these have been prosthesis models that imitate human conditions. We have developed a new rat model of implant-related osteomyelitis that mimics human osteomyelitis, to investigate the pathology of infection after orthopedic implant surgery. METHODS 2 wild-type strains of Staphylococcus aureus, MN8 and UAMS-1, and their corresponding mutants that are unable to produce poly-N-acetyl glucosamine (PNAG) (ica::tet) were injected into the medullary canals of the femur and tibia at 3 different doses: 10(2), 10(3), and > 10(4) CFU/rat. We measured clinical signs, inflammatory markers, radiographic signs, histopathology, and bacteriology in the infected animals. RESULTS An inoculum of at least 10(4) cfu of either wild-type bacterial strain resulted in histological, bacteriological, and radiographic signs of osteomyelitis with loosening of the prosthesis. An inoculum of 10(3) CFU gave signs of osteomyelitis but the prosthesis remained in situ. Bacterial inocula of 10(2) cfu gave no signs of osteolysis. INTERPRETATION We have established a new knee prosthesis model that is suitable for reliable induction of experimental implant-associated osteomyelitis with the prosthesis in situ, using a small inoculum of S. aureus. At a dose of 10(3) CFU/rat, bacteria unable to produce PNAG (ica::tet) had only minor defects in their virulence.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluating the Frequency of Implant-Supported Fixed Prosthesis Complications in Yazd Dental School in 2020

Introduction: Evaluating the frequency of complications in implant supported prosthesis such as screw loosening and porcelain fracture is important for prevention and management of these problems. The purpose of this study was to evaluate the frequency of implant-supported fixed prosthesis complications in Yazd dental school  in 2020. Methods: In this descriptive cross-sectional study, the pat...

متن کامل

Active and Passive Immunization Against Staphylococcus aureus Periprosthetic Osteomyelitis in Rats.

BACKGROUND/AIM Staphylococcus aureus infection associated with orthopedic implants cannot always be controlled. We used a knee prosthesis model with implant-related osteomyelitis in rats to explore induction of an effective immune response with active and passive immunization. MATERIALS AND METHODS Fifty-two Sprague-Dawley rats were divided into active (N=28) and passive immunization groups (...

متن کامل

Passive Controller Design for Swing Phase of a Single Axis Above-Knee Prosthesis

In this research we design a passive controller for an above knee prosthesis. The controller is a linear spring and damper for swing phase motion, parameters of which determined via optimization of adjustment of the prosthesis shank motion with a desired shank angle trajectory comes from experimental data. In this way, we exerted a certain thigh motion, hip movement included, into the system as...

متن کامل

Dynamics of a Running Below-Knee Prosthesis Compared to Those of a Normal Subject

The normal human running has been simulated by two-dimensional biped model with 7 segments. Series of normal running experiments were performed and data of ground reaction forces measured by force plate was analyzed and was fitted to some Fourier series. The model is capable to simulate running for different ages and weights at different running speeds. A proportional derivative control algorit...

متن کامل

مطالعه تنش‌های اطراف ایمپلنت به روش اجزای محدود در بریج‌های با ساپورت دندان/ایمپلنت در شرایط اتصال سخت و غیرسخت در پروتزهای سمان شونده

Background and Aims: Freestanding fixed partial prosthesis is considered the first choice whenever possible. However, anatomical limitations for implants and other reasons may create situation in which it would be preferable to connect the implants to teeth. A biomechanical dilemma in a tooth/implant-supported system comes from dissimilar mobility. This disparity cause the bridge to function as...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 84  شماره 

صفحات  -

تاریخ انتشار 2013