Efficacy of a heat exchanger mask in cold exercise-induced asthma.

نویسندگان

  • David A Beuther
  • Richard J Martin
چکیده

STUDY OBJECTIVES To determine the efficacy of a novel mask device in limiting cold air exercise-induced decline in lung function in subjects with a history of exercise-induced asthma (EIA). SETTING In spite of appropriate medical therapy, many asthma patients are limited in cold weather activities. DESIGN In study 1, 13 asthmatic subjects performed two randomized, single-blind treadmill exercise tests while breathing cold air (- 25 to - 15 degrees C) through a placebo or active heat exchanger mask. In study 2, five subjects with EIA performed three treadmill exercise tests while breathing cold air: one test using the heat exchanger mask, one test without the mask but with albuterol pretreatment, and one test with neither the mask nor albuterol pretreatment (unprotected exercise). For all studies, spirometry was performed before and at 5, 15, and 30 min after exercise challenge. PATIENTS For both studies, a total of 15 subjects with a history of asthma symptoms during cold air exercise were recruited. RESULTS In study 1, the mean decrease (+/- SE) in FEV1 was 19 +/- 4.9% with placebo, and 4.3 +/- 1.6% with the active device (p = 0.0002). The mean decrease in maximum mid-expiratory flow (FEF(25-75)) was 31 +/- 5.7% with placebo and 4.7 +/- 1.7% with the active device (p = 0.0002). In study 2, the mean decrease in FEV1 was 6.3 +/- 3.9%, 11 +/- 3.7%, and 28 +/- 10% for the heat exchanger mask, albuterol pretreatment, and unprotected exercises, respectively (p = 0.4375 for mask vs albuterol, p = 0.0625 for mask vs unprotected exercise). The mean decrease in FEF(25-75) was 10 +/- 4.8%, 23 +/- 6.0%, and 36 +/- 11%, respectively (p = 0.0625 for mask vs albuterol, p = 0.0625 for mask vs unprotected exercise). CONCLUSIONS This heat exchanger mask blocks cold exercise-induced decline in lung function at least as effectively as albuterol pretreatment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A mask to modify inspired air temperature and humidity and its effect on exercise induced asthma.

BACKGROUND Heat and moisture loss from the respiratory tract during exercise are important triggers of exercise induced asthma. METHODS A new heat and moisture exchange mask has been developed which both recovers exhaled heat and water and has a sufficiently low resistance for use during exercise. The effect of the mask on inspired air temperature was studied in four normal subjects. Eight as...

متن کامل

Prevention of asthma induced by cold air by cellulose-fabric face mask.

We have tested the effect of a porous cellulose fabric face mask. Nine asthmatic patients, anamnestically sensitive to cold, took part in exercise tests on an ergometer bicycle at a temperature of approximately -10 degrees C, with and without a face mask. For comparison, exercise tests were also performed with breathing taking place through a woolen scarf. Three minutes after finishing the exer...

متن کامل

Depression of salivary epidermal growth factor by smoking.

reduction in the forced expiratory volume in one second after exercise was calculated using the pre-exercise value as the baseline value. Statistical significance was calculated with Student's paired t test. The study was approved by the research ethical committee of the Faculty of Medicine, Queen's University, Belfast. The table shows the percentage reduction in forced expiratory volume in one...

متن کامل

Recovery benefits of using a heat and moisture exchange mask during sprint exercise in cold temperatures

Objectives Breathing cold air can lead to bronchoconstriction and peripheral vasoconstriction, both of which could impact muscular performance by affecting metabolic demands during exercise. Successful solutions dealing with these physiological changes during exercise in the cold has been lacking; therefore, we investigated the influence of a heat and moisture exchange mask during exercise in t...

متن کامل

Prevention of Facial Cold Injury with

The present study evaluated the thermodynamic characteristics of a prototype respiratory heat and moisture exchanger (HMS), particularly its ability to prevent cold injury to the face. The HME comprised a thermally insulated oro-nasal mask with a cylindrical heat and moisture exchanger protruding from the centre of the mask. The heat exchanging unit contained an aluminium “honeycomb” structure ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chest

دوره 129 5  شماره 

صفحات  -

تاریخ انتشار 2006