A method for reducing adaptor misalignment when testing gloves using ISO 10819.

نویسندگان

  • W P Smutz
  • R G Dong
  • B Han
  • A W Schopper
  • D E Welcome
  • M L Kashon
چکیده

OBJECTIVES International standard ISO 10819 was established in order to quantify the vibration attenuation characteristics of anti-vibration gloves. One problem that exists with the standard is possible misalignment of the palm adaptor that is placed underneath the test glove. If the adaptor becomes misaligned, the measured glove transmissibility will be lower than the actual value. A tri-axial accelerometer was installed in the adaptor and was used as the basis for providing visual feedback of the adaptor alignment to the test subjects. The objective of this study was to test the hypothesis that adaptor misalignment could be reduced by providing feedback to the test subjects. METHODS Eight male volunteers (mean age 24.8 yr) were used in the study. Each subject performed two sets of tests: the standard ISO 10819 glove test and the modified version. Three different anti-vibration gloves were tested. Glove transmissibility and adaptor misalignment were calculated for each glove. A three-way analysis of variance was used to analyze the results. RESULTS A comparison of the two testing methods showed that the modified glove testing method did reduce misalignment significantly, which, in turn, resulted in an increase in the measured glove transmissibility. CONCLUSIONS The proposed method greatly improved the standard deviation of transmissibility and made the test results more consistent.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of antivibration glove test protocols associated with the revision of ISO 10819.

Effects of modifying the palm adapter geometry on ISO 10819 antivibration glove test results were investigated. 30 rigid acrylic adapters were designed, fabricated, and evaluated. The length of the adapters that met ISO 10819 requirements covered 70-80% of the width of the palm. The upper curvatures of the adaptors were greater than or equal to the radius specified in ISO 10819:1996. Glove vibr...

متن کامل

Measurement of hand-vibration transmissibility by non-contact measurement techniques

Background: Workers who use hand-held vibrating tools may experience finger blanching attacks due to episodic vasospasm in the digital vessels. In occupational medicine, the pathological consequences to the exposure to handtransmitted vibration are known as vibration induced white finger (VWF). In many cases, workers are recommended to use anti-vibration gloves and a standard procedure (ISO 108...

متن کامل

Decrements Encountered when Wearing Hazardous Materials Gloves

Hazardous materials gloves (HAZMAT) are frequently worn when performing clinical technical skills, but it is unclear how sensory and motor performance is affected in these circumstances. In Experiment 1, two timed standardized manual dexterity tests, and a test of sensory function were administered. Glove use resulted in a decreased ability to manipulate small objects and a decreased sensitivit...

متن کامل

مقایسه تأثیر استفاده از دستکش لاتکس و نیتریل بر مهارت دست در جمعیت ایرانی

Introduction: Manual dexterity impairment due to wearing latex and nitrile gloves among health care employees and laboratory personnel can be a remarkable problem because of its adverse outcomes. The present study was conducted to “compare the effect of using latex and nitrile laboratory gloves on hand dexterity”. .Material and Method: In a semi experimental study design, 30 university were s...

متن کامل

طراحی و ساخت آداپتور آزمون حفاظهای شنوایی

Introduction: To determine the effectiveness of hearing protective devices that lack the technical information are one of the major challenges of occupational health experts to judge the impact of this exposure on reducing the level of occupational exposure to noise. The aim of this study was to design a built a hearing test adapter and expriment it to determine the reduction rate of earmuffs a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Annals of occupational hygiene

دوره 46 3  شماره 

صفحات  -

تاریخ انتشار 2002