Adaptive Optics Confocal Scanning Laser Ophthalmoscope
نویسندگان
چکیده
Scanning laser ophthalmoscope (SLO) was first presented by R. H. Webb (R. H. Webb, et al, 1987) in 1987, which is the same as a scanning laser microscope except that human eye is used as the objective lens and retina is usually the sample being imaged. With its high contrast real-time imaging and axial sectioning capability, SLO has many advantages and applications in retina imaging (Austin. Roorda, et al, 2002), eye tracking (D. X. Hammer, et al, 2005), hemodynamic (R. Daniel Ferguson, Daniel X. Hammer, 2004), tomography (Fernando Romero-Borja, et al, 2005), etc. However, due to ocular aberrations, resolution of image is dramatically degraded (R. H. Webb, et al, 1987), which results in that conventional SLOs always have large field (usually 10°~20°) and low resolution (lateral resolution>30μm, axial resolution>300μm for 6mm pupil).
منابع مشابه
Large-field-of-view, modular, stabilized, adaptive-optics-based scanning laser ophthalmoscope.
We describe the design and performance of an adaptive optics retinal imager that is optimized for use during dynamic correction for eye movements. The system incorporates a retinal tracker and stabilizer, a wide-field line scan scanning laser ophthalmoscope (SLO), and a high-resolution microelectromechanical-systems-based adaptive optics SLO. The detection system incorporates selection and posi...
متن کاملTheoretical modeling and evaluation of the axial resolution of the adaptive optics scanning laser ophthalmoscope.
We present axial resolution calculated using a mathematical model of the adaptive optics scanning laser ophthalmoscope (AOSLO). The peak intensity and the width of the axial intensity response are computed with the residual Zernike coefficients after the aberrations are corrected using adaptive optics for eight subjects and compared with the axial resolution of a diffraction-limited eye. The AO...
متن کاملTracking features in retinal images of adaptive optics confocal scanning laser ophthalmoscope using KLT-SIFT algorithm
With the use of adaptive optics (AO), high-resolution microscopic imaging of living human retina in the single cell level has been achieved. In an adaptive optics confocal scanning laser ophthalmoscope (AOSLO) system, with a small field size (about 1 degree, 280 μm), the motion of the eye severely affects the stabilization of the real-time video images and results in significant distortions of ...
متن کاملAdaptive optics scanning laser ophthalmoscope for stabilized retinal imaging.
A retinal imaging instrument that integrates adaptive optics (AO), scanning laser ophthalmoscopy (SLO), and retinal tracking components was built and tested. The system uses a Hartmann-Shack wave-front sensor (HS-WS) and MEMS-based deformable mirror (DM) for AO-correction of high-resolution, confocal SLO images. The system includes a wide-field line-scanning laser ophthalmoscope for easy orient...
متن کاملMeasurement of oxygen saturation in small retinal vessels with adaptive optics confocal scanning laser ophthalmoscope.
We have used an adaptive optics confocal scanning laser ophthalmoscope to assess oxygen saturation in small retinal vessels. Images of the vessels with a diameter smaller than 50 μm are recorded at oxygen sensitive and isosbestic wavelengths (680 and 796 nm, respectively). The vessel optical densities (ODs) are determined by a computer algorithm. Then, OD ratios (ODRs), which are inversely prop...
متن کاملOptical slicing of human retinal tissue in vivo with the adaptive optics scanning laser ophthalmoscope.
We present imaging results in human retinal tissue in vivo that allowed us to determine the axial resolution of the adaptive optics scanning laser ophthalmoscope (AOSLO). The instrument is briefly described, and the imaging results from human subjects are compared with (a) the estimated axial resolution values for a diffraction-limited, double-pass instrument and (b) the measured one for a cali...