Determination of Transformer Rating Based on Total Harmonic Distortion Under Balanced Conditions

نویسندگان

  • S. Masri
  • P.-W. Chan
چکیده

In the present article, the effects of a non-linear load under balanced conditions on the rating of a transformer are analysed. Non-linear loads are related to temperature increases in a transformer, which lead to deterioration and reduction of lifetime. Due to the unwanted effects of harmonic components in non-linear loads, the load connected to the transformer should be reduced. In other words, to supply a specific load, the rating of the transformer should be increased to sustain the rise in heat. The aforementioned methods of overcoming the effects of non-linear loads are known as de-rating. By assuming that the transformer’s rating is a linear function of the THD, a method of selecting the transformer’s rating based on the total harmonic distortion (THD) of the load was developed in the present study.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of Distribution Transformer Performance under Non-linear Balanced Load Conditions and Its Remedial Measures

In recent years there has been very extensive use of power electronic devices, which result in harmonic proliferation in the power distribution system. In this paper, as per IEEE C 57.110 standards, procedure to calculate total loss in the distribution transformer under non-linear distortion environment is proposed. The power factor capacitor performance under non-linear load conditions is also...

متن کامل

مبدل‌ AC-DC24 پالسه‌ مبتنی بر اتوترانسفورماتورچنگالی به منظور بهبود شاخص‌های کیفیت توان

In this paper, a 24-pulse ac-dc converter is designed, modeled and simulated based on a fork autotransformer to improve power quality indices. The use of autotransformer results in reduced kVA rating of the proposed topology as compared with the transformer based 24-pulse converter. Due to the proper flexibility of the proposed topology, it can be simply utilized in other similar applications. ...

متن کامل

A new passive 28-step current shaper for three-phase rectification

A new passive 28-step current shaper for three-phase rectification is proposed in this paper. With a phase-shifting transformer on the ac side and six interphase transformers on the dc side, per-phase input current can be shaped into a 28-step sinusoidal waveform. The total harmonic distortion of ac input currents obtained is 6.54%, lower than one-half of that in a conventional 12-pulse convert...

متن کامل

Design of Delta Primary - Transposed zigzag Secondary (DTz) Transformer to Minimize Harmonic Currents on the Three-phase Electric Power Distribution System

The delta primary transposed zigzag secondary (DTz) transformer has been designed and used to reduce the bad impacts of the harmonic in the distribution power system. The DTz transformer is constructed with delta connection in primary winding and the three transposed windings at the different core legs of secondary winding. The harmonic reduction method of the DTz transformer applies two basic ...

متن کامل

An improved current injection network for three-phase high-power-factor rectifiers that apply the third harmonic current injection

A novel current injection network for low-harmonic rectifiers that apply the third harmonic current injection is proposed in this letter. The current injection network requires one inductor, two capacitors, and one 1 : 1 transformer with voltampere rating of only 0.16% of the input power. The transformer is introduced to provide complete rejection of harmonic components of the injected currents...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012