Comparison of Conventional Radiography and Digital Computerized Radiography in Patients Presenting to Emergency Department
نویسندگان
چکیده
OBJECTIVES To compare the differences between conventional radiography and digital computerized radiography (CR) in patients presenting to the emergency department. METHODS The study enrolled consecutive patients presenting to the emergency department who needed chest radiography. Quality score of the radiogram was assessed with visual analogue score (VAS-100 mm), measured in terms of millimeters and recorded at the end of study. Examination time, interpretation time, total time, and cost of radiograms were calculated. RESULTS There were significant differences between conventional radiography and digital CR groups in terms of location unit (Care Unit, Trauma, Resuscitation), hour of presentation, diagnosis group, examination time, interpretation time, and examination quality. Examination times for conventional radiography and digital CR were 45.2 and 34.2 minutes, respectively. Interpretation times for conventional radiography and digital CR were 25.2 and 39.7 minutes, respectively. Mean radiography quality scores for conventional radiography and digital CR were 69.1 mm and 82.0 mm. Digital CR had a 1.05 TL cheaper cost per radiogram compared to conventional radiography. CONCLUSIONS Since interpretation of digital radiograms is performed via terminals inside the emergency department, the patient has to be left in order to interpret the digital radiograms, which prolongs interpretation times. We think that interpretation of digital radiograms with the help of a mobile device would eliminate these difficulties. Although the initial cost of setup of digital CR and PACS service is high at the emergency department, we think that Digital CR is more cost-effective than conventional radiography for emergency departments in the long-term.
منابع مشابه
Comparison of computerized digital and analog radiography for detection of bronchial pattern in dogs
Background: Analog radiography has been replaced with digital radiography for canine diagnostic imaging in many veterinary clinics. There is no data comparing these modalities in a veterinary clinical setting to detect bronchial pattern signs in dogs. Objectives: In this study, computerized digital radiography (CR) and analog radiography were compared for diagnosis of bronchial pattern in dogs....
متن کاملComparison of Accuracy and Observer Agreement in the Detection of Simulated External Root Resorption Using Conventional Digital Radiography and Digitally Filtered Radiography
Introduction: External root resorption is a clinical problem that often cannot be detected clinically. Thus, radiography plays a crucial role in its diagnosis. However, optimal radiographic quality with minimal radiation exposure {2.1 [EN] Verify English word/phrase choice} is an important factor in selecting the appropriate radiographic technique. The aim of this study was the comparison of ac...
متن کاملIn vitro Comparison of Conventional Film and Direct Digital Radiography in Proximal Caries Detection
Introduction: Various systems for intraoral digital radiography have been available as an alternative to film–based radiography. In consideration of several advantages of digital radiography such as less patient absorbed dose, manipulation of image quality and elimination of processing, it has been extensively used in different fields of dentistry in recent years. The purpose of this study wa...
متن کاملComparing the Accuracy of Cone Beam Computed Tomography,Digital Intraoral Radiography and Conventional Intraoral Radiography in the Measurement of Periodontal Bone Defects
Background and Aim: Cone beam computed tomography (CBCT) produces high-quality data in periodontal diagnosis and treatment planning. The aim of this study was to compare the accuracy of CBCT with intraoral digital and conventional radiography in the measurement of periodontal bone defects. Methods and Materials: In this diagnostic research, two hundred and eighteen artificial osseous d...
متن کاملQuality comparison of direct digital panoramic radiography and computed radiography panoramic
BACKGROUND AND AIM: Digital panoramic X-ray images can be captured using photostimulable phosphors or solid-state detectors (i.e. charge-coupled devices and Flat-Panels). The first category is defined as computed radiography (CR) or semi-direct radiography. The second technology that uses solid-state detectors is known as direct digital radiography (DDR). Both of these technologies have their o...
متن کامل