Analysis of the Principal Characteristics of the On-Board Throttle Cooling System of the IR Receiver on the Basis of a Tank with Cryogenic Fueling
نویسنده
چکیده
In this paper, a new tank with cryogenic charging (liquid nitrogen) is introduced. On the basis of this tank it is proposed to create a throttle cooling system, which may have enhanced characteristics compared with a throttle cooling system based on high pressure tank. This article deals with first results of tests of a tank with cryogenic charging (liquid nitrogen), which have been made at level of pressure to 4 MPa. Also it is shown that the behavior of parameters in a tank on time corresponds to calculation model.
منابع مشابه
How to Design a Cryogenic Joule-Thomson Cooling System: Case Study of Small Hydrogen Liquefier
Heat exchangers are the critical components of refrigeration and liquefaction processes. Selection of appropriate operational conditions for cryogenic recuperative heat exchanger and expansion valve operating in Joule-Thomson cooling system results in improving the performance and efficiency. In the current study, a straightforward procedure is introduced to design an efficient Joule-Thomson co...
متن کاملStudy of the performance of a solar adsorption cooling system
This article presents a transient model of a solar adsorption cooling system. A computer program has been developed to simulate the operation of a two bed silica gel- water adsorption cooling system as well as flat plate collectors and the hot water storage tank. This program is then utilized to simulate the performance of a sample solar adsorption cooling system used for cooling a set of r...
متن کاملMachinability Improvement of 17-4PH Stainless Steel by Cryogenic Cooling
17-4PH stainless steel is a martensitic precipitation hardening stainless steel that provides an outstanding combination of high strength, good corrosion resistance, good mechanical properties, good toughness in both base metal and welds, and short time, low-temperature heat treatments that minimize warpage and scaling. This valuable alloy is widely used in the aerospace, nuclear, chemical, pet...
متن کاملOptimization of Solar Absorption Cooling System Considering Hourly Analysis
Thermal modelling and optimal design of a solar absorption cooling system are presented, and hourly analysis is performed over the period of a year. Three design parameters are considered, then the Real Parameter Genetic Algorithm (RPGA) is applied to obtain the minimum total annual cost. The optimization results show that the solar cooling optimum configuration needs 1630 square meter collecto...
متن کاملAn Improved Modular Modeling for Analysis of Closed-Cycle Absorption Cooling Systems
A detailed modular modeling of an absorbent cooling system is presented in this paper. The model including the key components is described in terms of design parameters, inputs, control variables, and outputs. The model is used to simulate the operating conditions for estimating the behavior of individual components and system performance, and to conduct a sensitivity analysis based on the give...
متن کامل