Inflatable penile prosthesis implant length with baseline characteristic correlations: preliminary analysis of the PROPPER study

نویسندگان

  • Nelson Bennett
  • Gerard Henry
  • Edward Karpman
  • William Brant
  • LeRoy Jones
  • Mohit Khera
  • Tobias Kohler
  • Brian Christine
  • Eugene Rhee
  • Bryan Kansas
  • Anthony J. Bella
چکیده

Background "Prospective Registry of Outcomes with Penile Prosthesis for Erectile Restoration" (PROPPER) is a large, multi-institutional, prospective clinical study to collect, analyze, and report real-world outcomes for men implanted with penile prosthetic devices. We prospectively correlated co-morbid conditions and demographic data with implanted penile prosthesis size to enable clinicians to better predict implanted penis size following penile implantation. We present many new data points for the first time in the literature and postulate that radical prostatectomy (RP) is negatively correlated with penile corporal length. Methods Patient demographics, medical history, baseline characteristics and surgical details were compiled prospectively. Pearson correlation coefficient was generated for the correlation between demographic, etiology of ED, duration of ED, co-morbid conditions, pre-operative penile length (flaccid and stretched) and length of implanted penile prosthesis. Multivariate analysis was performed to define predictors of implanted prosthesis length. Results From June 2011 to June 2017, 1,135 men underwent primary implantation of penile prosthesis at a total of 11 study sites. Malleable (Spectra), 2-piece Ambicor, and 3-piece AMS 700 CX/LGX were included in the analysis. The most common patient comorbidities were CV disease (26.1%), DM (11.1%), and PD (12.4%). Primary etiology of ED: RP (27.4%), DM (20.3%), CVD (18.0%), PD (10.3%), and Priapism (1.4%), others (22.6%). Mean duration of ED is 6.2¡À4.1 years. Implant length was weakly negatively correlated with White/Caucasian (r=-0.18; P<0.01), history of RP (r=-0.13; P<0.01), PD as comorbidity (r=-0.16; P<0.01), venous leak (r=-0.08; P<0.01), and presence of stress incontinence (r=-0.13; P<0.01). Analyses showed weak positive correlations with Black/AA (r=0.32; P<0.01), CV disease as primary ED etiology (r=0.08; P<0.01) and pre-operative stretched penile length (r=0.18; P<0.01). There is a moderate correlation with pre-operative flaccid penile length (r=0.30; P<0.01). Conclusions Implanted penile prosthesis length is negatively correlated with some ethnic groups, prostatectomy, and incontinence. Positive correlates include CV disease, preoperative stretched penile length, and flaccid penile length.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Who, How, and What of Real-World Penile Implants Patients in 2015: The Propper (Prospective Registry of Outcomes with Penile Prosthesis for Erectile Restoration) Registry Baseline Data

Purpose: Heretofore, the published data on penile implant patients consisted generally of small series of single-surgeon, retrospective experiences rather than prospective or large, multicenter evaluations. This study establishes a baseline of data collection from PROPPER (Prospective Registry of Outcomes with Penile Prosthesis for Erectile Restoration). PROPPER is the first large, prospective,...

متن کامل

Patient satisfaction and penile morphology changes with postoperative penile rehabilitation 2 years after Coloplast Titan prosthesis

A common complaint after inflatable penile prosthesis surgery is reduced penile length. We previously reported how using the Coloplast Titan inflatable penile prosthesis with aggressive new length measurement technique (NLMT) coupled with postoperative IPP rehabilitation of the implant for 1-year helped to improve patient satisfaction and erectile penile measurements. This is a 2 years follow-u...

متن کامل

AB019. Scientific advances in inflatable penile prosthesis implant design and technology for the treatment of erectile dysfunction

It is generally accepted that the development of erectile dysfunction is frequently attributed to both psychogenic factors as well as physiological alterations in neural, vascular, hormonal and endothelial function. Despite the advent of oral and intracavernosal erectile drugs, penile prosthesis implant remains a relevant and desired treatment option as many men became refractory to medical the...

متن کامل

Penile prosthesis implant: scientific advances and technological innovations over the last four decades

Despite introduction of oral phosphodiesterase type 5 inhibitors and intracavernosal vasoactive agents, penile prosthesis implant remains a relevant and desired option with sales of penile prostheses continue to stay high, as many men became refractory to medical therapy and/or seeking a more effective and permanent therapy. There are two types of penile prosthesis implants: inflatable and non-...

متن کامل

AB020. Usefulness of RigiScan® evaluation of nocturnal penile tumescence

It is generally accepted that the development of erectile dysfunction is frequently attributed to both psychogenic factors as well as physiological alterations in neural, vascular, hormonal and endothelial function. Despite the advent of oral and intracavernosal erectile drugs, penile prosthesis implant remains a relevant and desired treatment option as many men became refractory to medical the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2017