Tomographic imaging in the diagnosis of pulmonary embolism: a comparison between V/Q lung scintigraphy in SPECT technique and multislice spiral CT.

نویسندگان

  • Patrick Reinartz
  • Joachim E Wildberger
  • Wolfgang Schaefer
  • Bernd Nowak
  • Andreas H Mahnken
  • Ulrich Buell
چکیده

UNLABELLED Although ventilation/perfusion (V/Q) lung scintigraphy is a well-accepted and frequently performed procedure in the diagnosis of pulmonary embolism, there is growing controversy about its relevance, particularly due to the increasing competition between scintigraphy and CT. Even though comparative studies between both modalities have already been performed, their results were highly inconsistent. Remarkably, in most of those studies, conventional planar perfusion scans were compared with tomographic images acquired using state-of-the-art CT scanners-a study design that cannot give impartial results. Hence, the aim of our study was a balanced comparison between V/Q lung scintigraphy and CT angiography using advanced imaging techniques for both modalities. METHODS A total of 83 patients with suspected pulmonary embolism were examined using V/Q lung scintigraphy in SPECT technique as well as 4-slice spiral CT. Ventilation scans were done using an ultrafine aerosol. Additionally, planar images in 8 views were extracted from the V/Q SPECT datasets. Two experienced referees assessed each of the 3 modalities. The final diagnosis was made at a consensus meeting while taking into account all of the imaging modalities, laboratory tests, clinical data, and evaluation of a follow-up period. RESULTS In the course of the consensus conference, pulmonary embolism was diagnosed in 37 of the 83 patients (44.6%). Compared with planar scintigraphy, SPECT raised the number of detectable defects at the segmental level by 12.8% (+11 defects; P = 0.401) and at the subsegmental level by 82.6% (+57 defects; P < 0.01). The sensitivity/specificity/accuracy of planar V/Q scintigraphy and V/Q SPECT was 0.76/0.85/0.81 and 0.97/0.91/0.94, respectively, compared with 0.86/0.98/0.93 for multislice CT. CONCLUSION SPECT and ultrafine aerosols are technical advancements that can substantially improve lung scintigraphy. Using advanced imaging techniques, V/Q scintigraphy and multislice spiral CT both yield an excellent and, in all aspects, comparable diagnostic accuracy, with CT leading in specificity while SPECT shows a superior sensitivity. Even though planar lung scintigraphy yields satisfactory results for a nontomographic modality, it does not compare with tomographic imaging.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Utility of Hybrid SPECT/CT Lung Perfusion Scintigraphy in Pulmonary Embolism Diagnosis.

BACKGROUND Pulmonary embolism (PE) is diagnosed either by ventilation/perfusion (V/Q) scintigraphy or pulmonary CT angiography. One of the imaging methods used in nuclear medicine is hybrid SPECT/CT scintigraphy. OBJECTIVES The aim of this study was to evaluate the utility of SPECT/CT(Q) scintigraphy in the diagnosis of PE and to compare SPECT/CT(Q) with planar(Q) and SPECT(Q) methods. METH...

متن کامل

Spurious lung perfusion ventilation defect on planar ventilation-perfusion scan detected by SPECT imaging

Pulmonary embolism (PE) is a preventable cause of morbidity and mortality which needs prompt recognition. Ventilation-perfusion (V/Q) scan is a well-established diagnostic test for evaluation of suspected PE. We report a 32-year-old woman with history of rheumatologic disease and acute dyspnea, who was referred for V/Q scintigraphy. The planar images revealed multiple mismatched defects through...

متن کامل

The Utility of Hybrid SPECT/CT Lung Perfusion Scintigraphy in Pulmonary Embolism Diagnosis

Background: Pulmonary embolism (PE) is diagnosed either by ventilation/perfusion (V/Q) scintigraphy or pulmonary CT angiography. One of the imaging methods used in nuclear medicine is hybrid SPECT/CT scintigraphy. Objectives: The aim of this study was to evaluate the utility of SPECT/CT(Q) scintigraphy in the diagnosis of PE and to compare SPECT/ CT(Q) with planar(Q) and SPECT(Q) methods. Metho...

متن کامل

The Utility of Hybrid SPECT/CT Lung Perfusion Scintigraphy in Pulmonary Embolism Diagnosis

Background: Pulmonary embolism (PE) is diagnosed either by ventilation/perfusion (V/Q) scintigraphy or pulmonary CT angiography. One of the imaging methods used in nuclear medicine is hybrid SPECT/CT scintigraphy. Objectives: The aim of this study was to evaluate the utility of SPECT/CT(Q) scintigraphy in the diagnosis of PE and to compare SPECT/ CT(Q) with planar(Q) and SPECT(Q) methods. Metho...

متن کامل

The Utility of Hybrid SPECT/CT Lung Perfusion Scintigraphy in Pulmonary Embolism Diagnosis

Background: Pulmonary embolism (PE) is diagnosed either by ventilation/perfusion (V/Q) scintigraphy or pulmonary CT angiography. One of the imaging methods used in nuclear medicine is hybrid SPECT/CT scintigraphy. Objectives: The aim of this study was to evaluate the utility of SPECT/CT(Q) scintigraphy in the diagnosis of PE and to compare SPECT/ CT(Q) with planar(Q) and SPECT(Q) methods. Metho...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 45 9  شماره 

صفحات  -

تاریخ انتشار 2004