Transverse Chromatic Aberration and Vision: Quantification and Impact across the Visual Field

نویسنده

  • SIMON WINTER
چکیده

The eye is our window to the world. Human vision has therefore been extensively studied over the years. However, in-depth studies are often either limited to our central visual field, or, when extended to the periphery, only correct optical errors related to a narrow spectrum of light. This thesis extends the current knowledge by considering the full visible spectrum over a wide visual field. A broad spectrum means that the wavelength dependence of light propagation inside the eye has to be considered; the optics of the eye will therefore not form a retinal image in the same location for all wavelengths, a phenomenon called chromatic aberration. We present here a new methodology to objectively measure the magnitude of transverse chromatic aberration (TCA) across the visual field of the human eye, and show that the ocular TCA increases linearly with off-axis angle (about 0.21 arcmin per degree for the spectral range from 543 nm to 842 nm). Moreover, we have implemented adaptive psychophysical methods to quantify the impact of TCA on central and peripheral vision. We have found that inducing additional TCA degrades peripheral grating detection acuity more than foveal resolution acuity (more than 0.05 logMAR per arcmin of induced TCA peripherally compared to 0.03 logMAR/arcmin foveally). As stimuli to evaluate peripheral vision, we recommend gratings that are obliquely-oriented relative to the visual field meridian. The results of this thesis have clinical relevance for improving peripheral vision and are equally important for retinal imaging techniques. To limit the negative impacts of TCA on vision, inducing additional TCA should be avoided when the peripheral refractive errors are to be corrected, such as for people suffering from macular degeneration and central visual field loss. In retinal imaging applications, TCA leads to lateral offsets when imaging is performed in more than one wavelength. Consequently, the measurement of TCA together with careful pupil alignment and subsequent compensation can improve the functionality of these instruments.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Construction of special eye models for investigation of chromatic and higher-order aberrations of eyes.

An achromatic element eliminating only longitudinal chromatic aberration (LCA) while maintaining transverse chromatic aberration (TCA) is established for the eye model, which involves the angle formed by the visual and optical axis. To investigate the impacts of higher-order aberrations on vision, the actual data of higher-order aberrations of human eyes with three typical levels are introduced...

متن کامل

Effect of induced transverse chromatic aberration on peripheral vision.

Transverse chromatic aberration (TCA) is one of the largest optical errors affecting the peripheral image quality in the human eye. However, the effect of chromatic aberrations on our peripheral vision is largely unknown. This study investigates the effect of prism-induced horizontal TCA on vision, in the central as well as in the 20° nasal visual field, for four subjects. Additionally, the mag...

متن کامل

Investigating sources of variability of monochromatic and transverse chromatic aberrations across eyes

Schematic eye models have typically been used to explain the average monochromatic and chromatic imaging properties of the eye. Both monochromatic aberrations and transverse chromatic aberration are known to vary widely across subjects. However, to our knowledge, the ability of schematic eye models to predict these individual variations has not been tested experimentally. We used a spatially re...

متن کامل

Effects of optimized photorefractive keratectomy (PRK) operation on the asphericity and high-order aberration changes

Background: Optimized is a common and important method in which aberrations are created by the device and the surgeon, but high-grade aberrations are out of the surgeon's control and are induced by the device in the patient. The aim of this study was the evaluation of out-of-control high-order aberration changes before and after PRK surgery and these impact on vision outcome. Materials and meth...

متن کامل

Wide-angle chromatic aberration corrector for the human eye.

The human eye is affected by large chromatic aberration. This may limit vision and makes it difficult to see fine retinal details in ophthalmoscopy. We designed and built a two-triplet system for correcting the average longitudinal chromatic aberration of the eye while keeping a reasonably wide field of view. Measurements in real eyes were conducted to examine the level and optical quality of t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016