La Jolla, Palo Alto, San Francisco, and Stanford, Calif. Background: The authors investigated thermal injury depth, inflammation, and scarring in human abdominal skin by comparing the histology of incisions made with a standard “cold” scalpel blade, conventional electrosurgery, and the PEAK PlasmaBlade, a novel, low-thermal-injury electrosurgical instrument. Methods: Approximately 6 and 3 weeks before abdominoplasty, full-thickness incisions were created in the abdominal pannus skin of 20 women, using a scalpel (scalpel), the PlasmaBlade, and a conventional electrosurgical instrument. Fresh (0-week) incisions were made immediately before surgery. After abdominoplasty, harvested incisions were analyzed for scar width, thermal injury depth, burst strength, and inflammatory response. Results: Acute thermal injury depth was reduced 74 percent in PlasmaBlade incisions compared with conventional electrosurgical instrument (p 0.001). Significant differences in inflammatory response were observed at 3 weeks, with mean CD3 response (T-lymphocytes) 40 percent (p 0.01) and 21 percent (p 0.12) higher for the conventional electrosurgical instrument and PlasmaBlade, respectively, compared with the scalpel. CD68 response (monocytes/macrophages) was 52 percent (p 0.05) and 16 percent (p 0.35) greater for a conventional electrosurgical instrument and the PlasmaBlade, respectively. PlasmaBlade incisions demonstrated 65 percent (p 0.001) and 42 percent (p 0.001) stronger burst strength than a conventional electrosurgical instrument, with equivalence to the scalpel at the 3and 6-week time points, respectively. Scar width was equivalent for the PlasmaBlade and the scalpel at both time points, and 25 percent (p 0.01) and 12 percent (p 0.15) less than for electrosurgery, respectively. Conclusions: PlasmaBlade incisions demonstrated reduced thermal injury depth, inflammatory response, and scar width in healing skin compared with electrosurgery. These results suggest that the PlasmaBlade may provide clinically meaningful advantages over conventional electrosurgery during human cutaneous wound healing. (Plast. Reconstr. Surg. 128: 104, 2011.) CLINICAL QUESTION/LEVEL OF EVIDENCE: Therapeutic, II.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Discussion: Comparative healing of human cutaneous surgical incisions created by the PEAK PlasmaBlade, conventional electrosurgery, and a standard scalpel.

BACKGROUND The authors investigated thermal injury depth, inflammation, and scarring in human abdominal skin by comparing the histology of incisions made with a standard "cold" scalpel blade, conventional electrosurgery, and the PEAK PlasmaBlade, a novel, low-thermal-injury electrosurgical instrument. METHODS Approximately 6 and 3 weeks before abdominoplasty, full-thickness incisions were cre...

متن کامل

Comparative healing of surgical incisions created by the PEAK PlasmaBlade, conventional electrosurgery, and a scalpel.

BACKGROUND The PEAK PlasmaBlade is a new electrosurgical device that uses pulsed radiofrequency to generate a plasma-mediated discharge along the exposed rim of an insulated blade, creating an effective cutting edge while the blade stays near body temperature. METHODS Full-thickness incisions were made on the dorsums of pigs with the PlasmaBlade, a conventional electrosurgical device, and a s...

متن کامل

Comparing the outcomes of incisions made by colorado microdissection needle, electrosurgery tip, and surgical blade during periodontal surgery: A randomized controlled trial

Context Electrosurgery offers many unique advantages such as hemostasis and precise tissue cutting; however, there are a number of disadvantages including thermal injury and delayed wound healing. Aims The aim of the present study was to compare the outcomes of incisions made by Colorado® microdissection needle, electrosurgery tip, and surgical blade during periodontal surgery. Settings and...

متن کامل

Advanced Cutting Effect System versus Cold Steel Scalpel: Comparative Wound Healing and Scar Formation in Targeted Surgical Applications

BACKGROUND Use of electrosurgery for skin incisions has been controversial due to concerns of delayed healing, excessive scarring, and increased infection. Recent studies using modern electrosurgical generators that produce pure sinusoidal "CUT" waveforms have shown reductions in thermal damage along incisions made with these devices compared with their predecessors. This study compares scar fo...

متن کامل

Comparing the complication of electrocautery and scalpel methods in surgical incisions of hysterectomy surgery

Aims: Surgical incisions have been performed by a scalpel for many years, and today the use of an alternative method, catheter incision, is increasing daily. This study aimed to evaluate the complications of use of electrocautery and scalpel in surgical incisions of the abdominal wall in hysterectomy surgery Materials and Methods: The present study is single-blind that was performed on 92 elig...