Improvement of diagnostic techniques and electrical circuit in azo dye degradation by high voltage electrical discharge
نویسندگان
چکیده
Fast electrical diagnostics and improvement of electrical circuits for methyl orange (MO) degradation by high voltage pulsed electrical discharge were investigated. To eliminate electromagnetic radiation, several effective methods were employed. RG 218 coaxial cable was substituted for the common transmission lines to transmit high voltage pulses, and multi-lines in parallel were earthed to avoid electromagnetic interference and, additionally, to reduce the stray inductance of the electrical circuit and increase the pulse rise rate to reduce the energy losses in the transmission system. The problem of the differences in the bandwidths of voltage and current probes causing an error in the calculation of energy dissipation was avoided by reducing the bandwidths of voltage and current measurements to the same value. The real discharge current was obtained by subtracting the capacitive current from the total current. The energy per pulse obtained in the reactor before and after improvement of the diagnostics and electrical circuit were 15.5 mJ and 26.8 mJ, respectively, and the energy efficiencies of MO degradation were 1.34 10 9 mol/J and 1.95 10 9 mol/J, respectively. 2008 Elsevier Ltd. All rights reserved.
منابع مشابه
Theoretical Studies of Electrical Characteristics of the Nitrogen Laser
A theoretical analysis of the circuits for a nitrogen laser driven by the Blumlein or capacitor charge transfer transmission line is given in detail. The electrical characteristics of the charge line for a special case of resonant charging are discussed and the effects of various parameters on voltage and current are investigated. By using MICRO-CAP software the transient behavior of the curren...
متن کاملUWB Mixer improvement with Regulated Voltage Source
This paper presents a design of an UWB downconversion integrated CMOS resistive ring mixer with Linear Voltage Regulator (LVR), to supply required biasing voltages for the mixer section. The designed mixer circuit has been optimized for using in heart rate extraction system with microwave Doppler radar at 2.4GHz frequency. This mixer needs 2 DC bias voltages equal to 0.5 and 1 volts for its bes...
متن کاملContributing factors on the removal of Azo-dyes from industrial wastewater: A comparison of the efficiency of sonocataysis and photocatalysis process
The influence of the number of operating parameters on photocatalytic and sonocatalytic Acid Red 88 degradation from an aqueous solution was investigated in this paper. The experimental results indicated that the sonocatalytic process with Ni-TiO2 was far more effective for the degradation of high concentration azo dyes, regardless of the process condition. In order to achieve a larger surface ...
متن کاملSwitched-Capacitor Dynamic Threshold PMOS (SC-DTPMOS) Transistor for High Speed Sub-threshold Applications
This work studies the effects of dynamic threshold design techniques on the speed and power of digital circuits. A new dynamic threshold transistor structure has been proposed to improve performances of digital circuits. The proposed switched-capacitor dynamic threshold PMOS (SC-DTPMOS) scheme employs a capacitor along with an NMOS switch in order to effectively reduce the threshold voltage of ...
متن کاملA Comparison Between Electrical Circuit and Finite Element Modeling Methods for Performance Analysis of a Three-Phase Induction Motor under Voltage Unbalance
Induction motor is the most popular load in the industry, it is very important to study about the effects of voltage quality on induction motor performance. One of the most important voltage quality problems in power system is voltage unbalance. This paper evaluates and compares two methods including finite element method (FEM) and equivalent electrical circuit simulation for investigation ...
متن کامل