Tissue response of a small saccular aneurysm after incomplete occlusion with a Guglielmi detachable coil.
نویسندگان
چکیده
A 49-year-old woman had a small saccular aneurysm that was incompletely occluded with a Guglielmi detachable coil (GDC). She died from rupture of another aneurysm 42 days after the treatment. Autopsy for the embolized aneurysm revealed no neoendothelium at the aneurysmal neck, but an organized thrombus was observed limited to the periphery of the aneurysmal lumen. Although isolation of the aneurysm was not apparent, loose embolization with this method may help to reinforce the aneurysmal wall.
منابع مشابه
Topic review: surface modifications enhancing biological activity of guglielmi detachable coils in treating intracranial aneurysms.
BACKGROUND Endovascular therapy with Guglielmi detachable coils is an accepted treatment option for patients with intracranial aneurysms. However, an emerging technology in the realm of endovascular tools is the use of traditional Guglielmi detachable coils with biologically active substances complexed to the coil surface to enhance aneurysm occlusion. METHODS We review the literature and cur...
متن کاملGuglielmi detachable coil treatment of ruptured saccular cerebral aneurysms: retrospective review of a 10-year single-center experience.
BACKGROUND AND PURPOSE We retrospectively analyzed our results with Guglielmi detachable coils (GDCs) for the endovascular occlusion of acutely ruptured saccular cerebral aneurysms over 10 years. METHODS Between 1991-2000, 83 patients (mean age, 56.1 years) with aneurysmal subarachnoid hemorrhage were treated with endovascular GDCs. Patients with aneurysms due to trauma or dissection and thos...
متن کاملCombined stent implantation and endosaccular coil placement for treatment of experimental wide-necked aneurysms: a feasibility study in swine.
PURPOSE To assess the feasibility of combining stent implantation in the parent artery with endosaccular coil placement for the treatment of experimentally created wide-necked aneurysms. METHODS Wide-necked aneurysms were surgically created on the common carotid artery in 12 swine. A metal stent was endovascularly implanted across each aneurysm neck and its effect documented anigiographically...
متن کاملDelayed reconfiguration of a Guglielmi detachable coil mass associated with late occlusion of an adjacent aneurysm and parent vessel.
We present a case of asymptomatic, progressive, late occlusion of the left superior cerebellar artery (SCA) and an aneurysm arising from the junction of the SCA and basilar artery after embolization of an adjacent aneurysm arising between the left posterior cerebral artery and the left SCA. The delayed occlusion was associated with reconfiguration of the Guglielmi detachable coils at the neck o...
متن کاملEmbolization of intracranial aneurysms with Guglielmi detachable coils augmented by microballoons.
We describe two cases in which balloons were used to aid in the occlusion of intracranial aneurysms with Guglielmi detachable coils. In both patients, initial attempts to place coils within the aneurysmal sac failed, as the loops of the coil repeatedly protruded through a wide aneurysmal neck into the parent vessel. Temporary balloons placed across the neck of these small, wide-necked aneurysms...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 20 4 شماره
صفحات -
تاریخ انتشار 1999