Optical-fiber-microsphere for remote fluorescence correlation spectroscopy.
نویسندگان
چکیده
Fluorescence correlation spectroscopy (FCS) is a versatile method that would greatly benefit to remote optical-fiber fluorescence sensors. However, the current state-of-the-art struggles with high background and low detection sensitivities that prevent the extension of fiber-based FCS down to the single-molecule level. Here we report the use of an optical fiber combined with a latex microsphere to perform FCS analysis. The sensitivity of the technique is demonstrated at the single molecule level thanks to a photonic nanojet effect. This offers new opportunities for reducing the bulky microscope setup and extending FCS to remote or in vivo applications.
منابع مشابه
Synthesize and Optical properties of ZnO: Eu Microspheres Based Nano-sheets at Direct and Indirect Excitation
Europium (Eu) doped ZnO microsphere based nano-sheets were synthesized through hydrothermal method. Effects of different concentrations of Europium on structural and optical properties of ZnO nano-sheets were investigated in detail. Prepared un-doped and Eu-doped ZnO samples were characterized using X-Ray diffraction (XRD), energy dispersive X-ray spectroscopy (EDX), scanning electron micro...
متن کاملDisposable microscope objective lenses for fluorescence correlation spectroscopy using latex microspheres.
We explore the combination of a latex microsphere with a low NA lens to form a high performance optical system, and enable the detection of single molecules by fluorescence correlation spectroscopy (FCS). Viable FCS experiments at concentrations 1-1000 nM with different objectives costing less than $40 are demonstrated. This offers a simple and low-cost alternative to the conventional complex m...
متن کاملNovel detection of aerosols: combined cavity ring-down and fluorescence spectroscopy.
High fluences inside cavity ring-down spectroscopy optical resonators lend themselves to fluorescence or Raman spectroscopy. An instrument at 488 nm was developed to measure extinction, and fluorescence of aerosols. A detection limit of 6 x 10;-9 cm;-1Hz;-1/2 (0.6 Mm;-1Hz;-1/2) was achieved. The fluorescence spectral power collected from a single fluorescent microsphere was 10 to 20 pW/nm. This...
متن کاملTwo-photon fluorescence correlation spectroscopy with high count rates and low background using dielectric microspheres
Two-photon excitation fluorescence is a powerful technique commonly used for biological imaging. However, the low absorption cross section of this non-linear process is a critical issue for performing biomolecular spectroscopy at the single molecule level. Enhancing the two-photon fluorescence signal would greatly improve the effectiveness of this technique, yet current methods struggle with me...
متن کاملHigh-efficiency single molecule fluorescence detection and correlation spectroscopy with dielectric microspheres
Microspheres made of high refractive index melamine resin are shown to enhance the fluorescence from single molecules in solution by seven-fold, and simultaneously reduce the observation volume by thirteen-fold, as compared to state-of-the-art confocal microscopy. This fluorescence enhancement is demonstrated to dramatically increase the signal-to-noise ratio in fluorescence correlation spectro...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Optics express
دوره 17 21 شماره
صفحات -
تاریخ انتشار 2009